• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:36:34 on February 24, 2002

    Entry number 3997

    keyword=End_of_Run_3072
    ****************************
     Run Number: 3072
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 982108       [+]: 481184       [-]: 480178       
    TIME  [0]: 14.238 mins  [+]: 6.986 mins  [-]: 6.984 mins  
    LIVE  [0]:  81.41%      [+]:  81.48%      [-]:  81.42%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.4/942695.1 Hz   T2[0] : 0.0/1451.0 Hz   T3[0] : 8.9/2682.1 Hz   T4[0] : 7.0/700.9 Hz   T5[0] :1377.0/1377.0 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 7.9/15759.7 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 9.4/940954.4 Hz   T2[+] : 0.0/1447.0 Hz   T3[+] : 8.9/2678.5 Hz   T4[+] : 7.0/700.1 Hz   T5[+] :1373.9/1373.9 Hz   T6[+] : 1.0/1.0  Hz   T7[+] : 7.9/15761.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 9.4/938856.7 Hz   T2[-] : 0.0/1433.8 Hz   T3[-] : 8.9/2681.0 Hz   T4[-] : 7.0/700.7 Hz   T5[-] :1372.1/1372.1 Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 7.9/15744.3 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8053/805313883  T2[0] :      1/1239585  T3[0] :   7637/2291196  T4[0] :   5987/598755   T5[0] :1176298/1176298  T6[0] :    827/827      T7[0] :   6731/13462993  T8[0] :    854/874770   
    T1[+] :   3943/394389482  T2[+] :      0/606505   T3[+] :   3742/1122671  T4[+] :   2934/293424   T5[+] : 575841/575841   T6[+] :    402/402      T7[+] :   3303/6606197  T8[+] :    419/429197   
    T1[-] :   3934/393443324  T2[-] :      0/600861   T3[-] :   3745/1123511  T4[-] :   2936/293625   T5[-] : 574996/574996   T6[-] :    410/410      T7[-] :   3298/6597914  T8[-] :    419/429124   
    
    AVERAGE CURRENT
    BCM x1 : 22.2911uA  BCM x3 : 22.3299uA  BCM x10: 22.3155uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    903.5 ppm     BCM u3 :    872.4 ppm     BCM u10:    883.4 ppm     
    BCM d1 :    910.9 ppm     BCM d3 :    856.2 ppm     BCM d10:    871.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01858        BCM u3 [0]:0.01864        BCM u10[0]:0.01867        
    BCM u1 [+]:0.009123       BCM u3 [+]:0.009151       BCM u10[+]:0.009166       
    BCM u1 [-]:0.009105       BCM u3 [-]:0.009133       BCM u10[-]:0.009148       
    
    BCM d1 [0]:0.0195         BCM d3 [0]:0.01951        BCM d10[0]:0.01946        
    BCM d1 [+]:0.009576       BCM d3 [+]:0.009581       BCM d10[+]:0.009553       
    BCM d1 [-]:0.009557       BCM d3 [-]:0.009563       BCM d10[-]:0.009535       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3072 at Sun Feb 24 17:36:25 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -0.634766
    Left Arm Bottom VDC Current : -2.97852
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.51
    Left Arm Q2 momentum : 2.93895
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1169.94
    Left Arm Q3 momentum : 2.93867
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.7831
    Current on Unser monitor : 37.2251
    Current on Upstream bcm : 29.6622
    Current on Downstream bcm : 29.9041
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.7956
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.01
    Delta(E)/E width (MV_AI_DXWID) : 0.4064
    IPM1C12.XPOS : 0.015206
    IPM1H04A.XPOS : 0.346133
    IPM1H04A.YPOS : 0.354894
    IPM1H04B.XPOS : 0.0449167
    IPM1H04B.YPOS : 1.61683
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260949
    HacL_alignPITCH : -0.163405
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 412
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.365273
    Target OTR y-position : 2.11477
    Target OTR x-width : 0.879636
    Target OTR y-width : 0.969081
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.747801
    Arc OTR y-position : 0.286068
    Arc OTR x-width : 4.40146
    Arc OTR y-width : 3.54309
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391