• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:01:12 on February 24, 2002

    Entry number 4015

    keyword=End_of_Run_3083
    ****************************
     Run Number: 3083
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 983158       [+]: 481879       [-]: 480087       
    TIME  [0]: 10.942 mins  [+]: 5.368 mins  [-]: 5.367 mins  
    LIVE  [0]:  81.19%      [+]:  81.27%      [-]:  81.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.3/1225385.0 Hz   T2[0] : 0.0/1907.4 Hz   T3[0] :11.6/3486.2 Hz   T4[0] : 9.1/907.4 Hz   T5[0] :1799.4/1799.4 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.2/20304.8 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.2/1223044.7 Hz   T2[+] : 0.0/1896.7 Hz   T3[+] :11.6/3485.2 Hz   T4[+] : 9.1/906.5 Hz   T5[+] :1796.1/1796.1 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.2/20312.0 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.2/1220240.9 Hz   T2[-] : 0.0/1890.0 Hz   T3[-] :11.6/3482.4 Hz   T4[-] : 9.1/907.0 Hz   T5[-] :1790.8/1790.8 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.1/20275.2 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8045/804519129  T2[0] :      1/1252303  T3[0] :   7629/2288846  T4[0] :   5957/595776   T5[0] :1181366/1181366  T6[0] :    635/635      T7[0] :   6665/13330972  T8[0] :    656/672301   
    T1[+] :   3939/393902808  T2[+] :      0/610864   T3[+] :   3741/1122478  T4[+] :   2919/291947   T5[+] : 578468/578468   T6[+] :    311/311      T7[+] :   3270/6541835  T8[+] :    322/329797   
    T1[-] :   3929/392961646  T2[-] :      0/608653   T3[-] :   3738/1121449  T4[-] :   2920/292088   T5[-] : 576694/576694   T6[-] :    314/314      T7[-] :   3264/6529336  T8[-] :    322/329765   
    
    AVERAGE CURRENT
    BCM x1 : 28.9567uA  BCM x3 : 29.0146uA  BCM x10: 28.9937uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    928.4 ppm     BCM u3 :    903.6 ppm     BCM u10:    912.3 ppm     
    BCM d1 :    930.3 ppm     BCM d3 :    889.5 ppm     BCM d10:    902.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01854        BCM u3 [0]:0.01861        BCM u10[0]:0.01864        
    BCM u1 [+]:0.009103       BCM u3 [+]:0.009136       BCM u10[+]:0.009151       
    BCM u1 [-]:0.009085       BCM u3 [-]:0.009119       BCM u10[-]:0.009133       
    
    BCM d1 [0]:0.01948        BCM d3 [0]:0.01949        BCM d10[0]:0.01943        
    BCM d1 [+]:0.009561       BCM d3 [+]:0.009566       BCM d10[+]:0.009538       
    BCM d1 [-]:0.009542       BCM d3 [-]:0.009548       BCM d10[-]:0.009519       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3083 at Sun Feb 24 20:01:01 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.83203
    Left Arm Bottom VDC Current : -2.49023
    Left Arm Q1 power supply current : 2210.95
    Left Arm Q1 momentum : 2.9388
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.56
    Left Arm Q2 momentum : 2.93906
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.07
    Left Arm Q3 momentum : 2.9394
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8972
    Current on Unser monitor : 36.8763
    Current on Upstream bcm : 29.7641
    Current on Downstream bcm : 30.0303
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0332
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.09
    Delta(E)/E width (MV_AI_DXWID) : 0.408006
    IPM1C12.XPOS : 0.022006
    IPM1H04A.XPOS : 0.329292
    IPM1H04A.YPOS : 0.347424
    IPM1H04B.XPOS : 0.0783946
    IPM1H04B.YPOS : 1.65563
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0820312
    HacL_alignROLL : 0.260583
    HacL_alignPITCH : -0.164435
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 424
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.359891
    Target OTR y-position : 2.1232
    Target OTR x-width : 0.893077
    Target OTR y-width : 0.966602
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.7249
    Arc OTR y-position : 0.263288
    Arc OTR x-width : 4.39858
    Arc OTR y-width : 3.54219
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391