    Log entry time 20:59:46 on February 24, 2002

    Entry number 4025

    keyword=End_of_Run_3088
    ****************************
     Run Number: 3088
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 981392       [+]: 480377       [-]: 480364       
    TIME  [0]: 11.106 mins  [+]: 5.448 mins  [-]: 5.449 mins  
    LIVE  [0]:  81.44%      [+]:  81.46%      [-]:  81.52%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.0/1201480.8 Hz   T2[0] : 0.0/1865.8 Hz   T3[0] :11.4/3430.6 Hz   T4[0] : 8.9/894.8 Hz   T5[0] :1764.2/1764.2 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.0/19996.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.0/1199404.5 Hz   T2[+] : 0.0/1855.5 Hz   T3[+] :11.4/3431.7 Hz   T4[+] : 9.0/896.0 Hz   T5[+] :1759.7/1759.7 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.0/20001.9 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.0/1196419.7 Hz   T2[-] : 0.0/1849.2 Hz   T3[-] :11.4/3424.2 Hz   T4[-] : 8.9/892.2 Hz   T5[-] :1758.1/1758.1 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.0/19970.5 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8005/800596882  T2[0] :      1/1243246  T3[0] :   7619/2285950  T4[0] :   5962/596270   T5[0] :1175541/1175541  T6[0] :    645/645      T7[0] :   6662/13324429  T8[0] :    666/682334   
    T1[+] :   3920/392044810  T2[+] :      0/606502   T3[+] :   3739/1121713  T4[+] :   2928/292868   T5[+] : 575188/575188   T6[+] :    317/317      T7[+] :   3268/6537933  T8[+] :    326/334711   
    T1[-] :   3911/391160299  T2[-] :      0/604566   T3[-] :   3731/1119510  T4[-] :   2917/291705   T5[-] : 574793/574793   T6[-] :    313/313      T7[-] :   3264/6529212  T8[-] :    326/334789   
    
    AVERAGE CURRENT
    BCM x1 : 28.5154uA  BCM x3 : 28.5719uA  BCM x10: 28.5514uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1038 ppm     BCM u3 :     1013 ppm     BCM u10:     1020 ppm     
    BCM d1 :     1040 ppm     BCM d3 :    996.2 ppm     BCM d10:     1010 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01854        BCM u3 [0]:0.0186         BCM u10[0]:0.01863        
    BCM u1 [+]:0.0091         BCM u3 [+]:0.009133       BCM u10[+]:0.009147       
    BCM u1 [-]:0.009083       BCM u3 [-]:0.009117       BCM u10[-]:0.009131       
    
    BCM d1 [0]:0.01947        BCM d3 [0]:0.01947        BCM d10[0]:0.01942        
    BCM d1 [+]:0.009556       BCM d3 [+]:0.009561       BCM d10[+]:0.009533       
    BCM d1 [-]:0.009539       BCM d3 [-]:0.009544       BCM d10[-]:0.009516       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3088 at Sun Feb 24 20:59:39 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -1.66016
    Left Arm Bottom VDC Current : -1.07422
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.8
    Left Arm Q2 momentum : 2.93963
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.11
    Left Arm Q3 momentum : 2.93877
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8671
    Current on Unser monitor : 38.6559
    Current on Upstream bcm : 29.779
    Current on Downstream bcm : 29.9753
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.1267
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.03
    Delta(E)/E width (MV_AI_DXWID) : 0.390535
    IPM1C12.XPOS : 0.016213
    IPM1H04A.XPOS : 0.337271
    IPM1H04A.YPOS : 0.371327
    IPM1H04B.XPOS : 0.0753578
    IPM1H04B.YPOS : 1.6585
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0834961
    HacL_alignROLL : 0.260657
    HacL_alignPITCH : -0.164033
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 424
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.361588
    Target OTR y-position : 2.12184
    Target OTR x-width : 0.885424
    Target OTR y-width : 0.9693
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.738464
    Arc OTR y-position : 0.265835
    Arc OTR x-width : 4.39887
    Arc OTR y-width : 3.54194
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391