• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:12:35 on February 24, 2002

    Entry number 4027

    keyword=End_of_Run_3089
    ****************************
     Run Number: 3089
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 983646       [+]: 481466       [-]: 480962       
    TIME  [0]: 11.097 mins  [+]: 5.443 mins  [-]: 5.443 mins  
    LIVE  [0]:  81.56%      [+]:  81.54%      [-]:  81.67%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.0/1204743.9 Hz   T2[0] : 0.0/1868.9 Hz   T3[0] :11.4/3434.4 Hz   T4[0] : 9.0/896.0 Hz   T5[0] :1767.1/1767.1 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.0/20035.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.0/1202511.5 Hz   T2[+] : 0.0/1857.8 Hz   T3[+] :11.4/3434.5 Hz   T4[+] : 9.0/898.2 Hz   T5[+] :1763.6/1763.6 Hz   T6[+] : 0.9/0.9  Hz   T7[+] :10.0/20057.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.0/1199650.9 Hz   T2[-] : 0.0/1851.4 Hz   T3[-] :11.4/3429.1 Hz   T4[-] : 8.9/892.3 Hz   T5[-] :1758.7/1758.7 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.0/19990.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8021/802124108  T2[0] :      1/1244306  T3[0] :   7622/2286660  T4[0] :   5965/596591   T5[0] :1176519/1176519  T6[0] :    645/645      T7[0] :   6669/13339655  T8[0] :    665/681784   
    T1[+] :   3927/392706904  T2[+] :      0/606711   T3[+] :   3738/1121622  T4[+] :   2933/293337   T5[+] : 575935/575935   T6[+] :    301/301      T7[+] :   3275/6550095  T8[+] :    326/334410   
    T1[-] :   3917/391799674  T2[-] :      0/604661   T3[-] :   3733/1119912  T4[-] :   2914/291416   T5[-] : 574390/574390   T6[-] :    331/331      T7[-] :   3264/6528756  T8[-] :    326/334433   
    
    AVERAGE CURRENT
    BCM x1 : 28.5816uA  BCM x3 : 28.6382uA  BCM x10: 28.6178uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    972.2 ppm     BCM u3 :    942.7 ppm     BCM u10:    953.8 ppm     
    BCM d1 :    976.2 ppm     BCM d3 :    926.2 ppm     BCM d10:    943.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01856        BCM u3 [0]:0.01863        BCM u10[0]:0.01866        
    BCM u1 [+]:0.009112       BCM u3 [+]:0.009145       BCM u10[+]:0.009159       
    BCM u1 [-]:0.009095       BCM u3 [-]:0.009128       BCM u10[-]:0.009142       
    
    BCM d1 [0]:0.0195         BCM d3 [0]:0.0195         BCM d10[0]:0.01945        
    BCM d1 [+]:0.009569       BCM d3 [+]:0.009574       BCM d10[+]:0.009546       
    BCM d1 [-]:0.009551       BCM d3 [-]:0.009557       BCM d10[-]:0.009528       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3089 at Sun Feb 24 21:12:29 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 2.14844
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18748
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.56
    Left Arm Q2 momentum : 2.93907
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.12
    Left Arm Q3 momentum : 2.93913
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.9539
    Current on Unser monitor : 38.2491
    Current on Upstream bcm : 29.8053
    Current on Downstream bcm : 30.1026
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.2832
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.22
    Delta(E)/E width (MV_AI_DXWID) : 0.412374
    IPM1C12.XPOS : -0.0011802
    IPM1H04A.XPOS : 0.330288
    IPM1H04A.YPOS : 0.327701
    IPM1H04B.XPOS : 0.0785548
    IPM1H04B.YPOS : 1.6618
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260583
    HacL_alignPITCH : -0.163958
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 424
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.365621
    Target OTR y-position : 2.11905
    Target OTR x-width : 0.886412
    Target OTR y-width : 0.968389
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.73778
    Arc OTR y-position : 0.281884
    Arc OTR x-width : 4.40347
    Arc OTR y-width : 3.54218
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391