• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:59:26 on February 24, 2002

    Entry number 4043

    keyword=End_of_Run_3098
    ****************************
     Run Number: 3098
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 984279       [+]: 482744       [-]: 480826       
    TIME  [0]: 10.457 mins  [+]: 5.131 mins  [-]: 5.131 mins  
    LIVE  [0]:  81.38%      [+]:  81.41%      [-]:  81.46%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.8/1278441.9 Hz   T2[0] : 0.0/1976.1 Hz   T3[0] :12.2/3661.9 Hz   T4[0] : 9.6/956.2 Hz   T5[0] :1880.6/1880.6 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21361.3 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.8/1276280.8 Hz   T2[+] : 0.0/1967.9 Hz   T3[+] :12.2/3659.8 Hz   T4[+] : 9.5/954.1 Hz   T5[+] :1879.0/1879.0 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.7/21371.7 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.7/1273014.5 Hz   T2[-] : 0.0/1956.5 Hz   T3[-] :12.2/3658.3 Hz   T4[-] : 9.6/957.0 Hz   T5[-] :1870.0/1870.0 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.7/21328.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8021/802121158  T2[0] :      1/1239842  T3[0] :   7658/2297545  T4[0] :   5999/599944   T5[0] :1179918/1179918  T6[0] :    607/607      T7[0] :   6701/13402521  T8[0] :    627/642479   
    T1[+] :   3929/392924970  T2[+] :      0/605856   T3[+] :   3755/1126730  T4[+] :   2937/293736   T5[+] : 578482/578482   T6[+] :    305/305      T7[+] :   3289/6579630  T8[+] :    307/315256   
    T1[-] :   3919/391946753  T2[-] :      0/602388   T3[-] :   3754/1126346  T4[-] :   2946/294638   T5[-] : 575748/575748   T6[-] :    295/295      T7[-] :   3283/6566758  T8[-] :    307/315278   
    
    AVERAGE CURRENT
    BCM x1 : 30.4535uA  BCM x3 : 30.5169uA  BCM x10: 30.4952uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1021 ppm     BCM u3 :    993.2 ppm     BCM u10:     1004 ppm     
    BCM d1 :     1026 ppm     BCM d3 :    977.3 ppm     BCM d10:    992.8 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01864        BCM u3 [0]:0.01871        BCM u10[0]:0.01874        
    BCM u1 [+]:0.009152       BCM u3 [+]:0.009186       BCM u10[+]:0.009201       
    BCM u1 [-]:0.009134       BCM u3 [-]:0.009169       BCM u10[-]:0.009183       
    
    BCM d1 [0]:0.01958        BCM d3 [0]:0.01959        BCM d10[0]:0.01953        
    BCM d1 [+]:0.009614       BCM d3 [+]:0.009618       BCM d10[+]:0.00959        
    BCM d1 [-]:0.009594       BCM d3 [-]:0.0096         BCM d10[-]:0.009572       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3098 at Sun Feb 24 22:59:19 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.51562
    Left Arm Bottom VDC Current : 1.61133
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18748
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.43
    Left Arm Q2 momentum : 2.93875
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.15
    Left Arm Q3 momentum : 2.9392
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 14.9942
    Current on Unser monitor : 38.588
    Current on Upstream bcm : 29.9628
    Current on Downstream bcm : 0.0255141
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.648
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.19
    Delta(E)/E width (MV_AI_DXWID) : 0.427107
    IPM1C12.XPOS : -0.0110301
    IPM1H04A.XPOS : 0.355439
    IPM1H04A.YPOS : 0.360065
    IPM1H04B.XPOS : 0.0911805
    IPM1H04B.YPOS : 1.65365
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.11377
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260583
    HacL_alignPITCH : -0.16348
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 424
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.378573
    Target OTR y-position : 2.12064
    Target OTR x-width : 0.88641
    Target OTR y-width : 0.96573
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.733648
    Arc OTR y-position : 0.27658
    Arc OTR x-width : 4.40785
    Arc OTR y-width : 3.53965
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391