• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:45:43 on February 25, 2002

    Entry number 4093

    keyword=End_of_Run_3120
    ****************************
     Run Number: 3120
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 981805       [+]: 481024       [-]: 480037       
    TIME  [0]: 11.188 mins  [+]: 5.489 mins  [-]: 5.490 mins  
    LIVE  [0]:  81.63%      [+]:  81.69%      [-]:  81.69%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.0/1195532.4 Hz   T2[0] : 0.0/1851.9 Hz   T3[0] :11.4/3413.9 Hz   T4[0] : 8.9/890.0 Hz   T5[0] :1747.5/1747.5 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 9.9/19868.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :11.9/1193142.3 Hz   T2[+] : 0.0/1839.8 Hz   T3[+] :11.4/3416.1 Hz   T4[+] : 8.9/888.5 Hz   T5[+] :1744.0/1744.0 Hz   T6[+] : 0.9/0.9  Hz   T7[+] : 9.9/19880.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :11.9/1190713.5 Hz   T2[-] : 0.0/1836.6 Hz   T3[-] :11.4/3406.9 Hz   T4[-] : 8.9/889.8 Hz   T5[-] :1739.9/1739.9 Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 9.9/19834.1 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8025/802543182  T2[0] :      1/1243170  T3[0] :   7638/2291688  T4[0] :   5974/597435   T5[0] :1173095/1173095  T6[0] :    650/650      T7[0] :   6668/13337175  T8[0] :    671/687396   
    T1[+] :   3929/392955120  T2[+] :      0/605936   T3[+] :   3750/1125065  T4[+] :   2926/292631   T5[+] : 574372/574372   T6[+] :    294/294      T7[+] :   3273/6547401  T8[+] :    329/337249   
    T1[-] :   3922/392207547  T2[-] :      0/604955   T3[-] :   3740/1122186  T4[-] :   2930/293096   T5[-] : 573119/573119   T6[-] :    344/344      T7[-] :   3266/6533112  T8[-] :    329/337294   
    
    AVERAGE CURRENT
    BCM x1 : 28.4086uA  BCM x3 : 28.4660uA  BCM x10: 28.4459uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    796.6 ppm     BCM u3 :    774.9 ppm     BCM u10:    781.6 ppm     
    BCM d1 :      802 ppm     BCM d3 :      763 ppm     BCM d10:    773.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0186         BCM u3 [0]:0.01867        BCM u10[0]:0.0187         
    BCM u1 [+]:0.009132       BCM u3 [+]:0.009166       BCM u10[+]:0.00918        
    BCM u1 [-]:0.009119       BCM u3 [-]:0.009153       BCM u10[-]:0.009167       
    
    BCM d1 [0]:0.01954        BCM d3 [0]:0.01955        BCM d10[0]:0.01949        
    BCM d1 [+]:0.00959        BCM d3 [+]:0.009595       BCM d10[+]:0.009567       
    BCM d1 [-]:0.009576       BCM d3 [-]:0.009582       BCM d10[-]:0.009554       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3120 at Mon Feb 25 04:45:35 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.32031
    Left Arm Bottom VDC Current : -2.29492
    Left Arm Q1 power supply current : 2210.95
    Left Arm Q1 momentum : 2.9388
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.36
    Left Arm Q2 momentum : 2.93859
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.02
    Left Arm Q3 momentum : 2.93888
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8395
    Current on Unser monitor : 36.8578
    Current on Upstream bcm : 29.7113
    Current on Downstream bcm : 29.9676
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.9883
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.83
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00239432
    IPM1H04A.XPOS : 0.336821
    IPM1H04A.YPOS : 0.354151
    IPM1H04B.XPOS : 0.0765042
    IPM1H04B.YPOS : 1.64242
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : -0.0820312
    HacL_alignROLL : 0.260875
    HacL_alignPITCH : -0.163807
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 414
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.384858
    Target OTR y-position : 2.11516
    Target OTR x-width : 0.889887
    Target OTR y-width : 0.967809
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.754398
    Arc OTR y-position : 0.289734
    Arc OTR x-width : 4.38954
    Arc OTR y-width : 3.53843
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391