• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 08:21:42 on February 25, 2002

    Entry number 4130

    keyword=End_of_Run_3138
    ****************************
     Run Number: 3138
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 981578       [+]: 480905       [-]: 480152       
    TIME  [0]: 11.065 mins  [+]: 5.430 mins  [-]: 5.430 mins  
    LIVE  [0]:  81.81%      [+]:  81.79%      [-]:  81.92%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.0/1201443.8 Hz   T2[0] : 0.0/1834.9 Hz   T3[0] :11.6/3480.3 Hz   T4[0] : 9.1/907.1 Hz   T5[0] :1762.4/1762.4 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.2/20320.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.0/1199121.6 Hz   T2[+] : 0.0/1822.9 Hz   T3[+] :11.6/3480.3 Hz   T4[+] : 9.1/907.3 Hz   T5[+] :1759.8/1759.8 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.2/20325.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.0/1196619.0 Hz   T2[-] : 0.0/1819.5 Hz   T3[-] :11.6/3475.1 Hz   T4[-] : 9.1/906.4 Hz   T5[-] :1754.2/1754.2 Hz   T6[-] : 0.9/0.9  Hz   T7[-] :10.1/20296.2 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   7976/797622585  T2[0] :      1/1218175  T3[0] :   7701/2310549  T4[0] :   6021/602194   T5[0] :1170043/1170043  T6[0] :    642/642      T7[0] :   6745/13490473  T8[0] :    663/679820   
    T1[+] :   3906/390685307  T2[+] :      0/593914   T3[+] :   3779/1133931  T4[+] :   2956/295604   T5[+] : 573364/573364   T6[+] :    324/324      T7[+] :   3311/6622119  T8[+] :    325/333629   
    T1[-] :   3898/389882760  T2[-] :      0/592843   T3[-] :   3774/1132269  T4[-] :   2953/295314   T5[-] : 571554/571554   T6[-] :    303/303      T7[-] :   3306/6612907  T8[-] :    325/333640   
    
    AVERAGE CURRENT
    BCM x1 : 28.9436uA  BCM x3 : 29.0023uA  BCM x10: 28.9818uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    868.1 ppm     BCM u3 :    841.9 ppm     BCM u10:    851.9 ppm     
    BCM d1 :    872.9 ppm     BCM d3 :    828.8 ppm     BCM d10:    840.8 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01874        BCM u3 [0]:0.01881        BCM u10[0]:0.01884        
    BCM u1 [+]:0.009205       BCM u3 [+]:0.009238       BCM u10[+]:0.009253       
    BCM u1 [-]:0.009189       BCM u3 [-]:0.009223       BCM u10[-]:0.009238       
    
    BCM d1 [0]:0.01969        BCM d3 [0]:0.0197         BCM d10[0]:0.01964        
    BCM d1 [+]:0.009667       BCM d3 [+]:0.009672       BCM d10[+]:0.009644       
    BCM d1 [-]:0.00965        BCM d3 [-]:0.009656       BCM d10[-]:0.009628       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3138 at Mon Feb 25 08:21:32 EST 2002
    Left Arm D1 momentum : 2.93899
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.83203
    Left Arm Bottom VDC Current : 1.95312
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.28
    Left Arm Q2 momentum : 2.9384
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1169.93
    Left Arm Q3 momentum : 2.93864
    Left Arm Q3 gauss meter : 0.5856
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8429
    Current on Unser monitor : 38.1099
    Current on Upstream bcm : 29.6967
    Current on Downstream bcm : 29.9891
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0817
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.71
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.000536829
    IPM1H04A.XPOS : 0.315128
    IPM1H04A.YPOS : 0.366542
    IPM1H04B.XPOS : 0.0694595
    IPM1H04B.YPOS : 1.6565
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0834961
    HacL_alignROLL : 0.259624
    HacL_alignPITCH : -0.163882
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 426
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.38195
    Target OTR y-position : 2.1181
    Target OTR x-width : 0.893511
    Target OTR y-width : 0.966778
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.725594
    Arc OTR y-position : 0.262359
    Arc OTR x-width : 4.40764
    Arc OTR y-width : 3.54418
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407