    Log entry time 18:27:56 on February 25, 2002

    Entry number 4218

    keyword=End_of_Run_3183
    ****************************
     Run Number: 3183
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e) production,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 983238       [+]: 481040       [-]: 481298       
    TIME  [0]: 11.058 mins  [+]: 5.425 mins  [-]: 5.425 mins  
    LIVE  [0]:  81.96%      [+]:  81.95%      [-]:  82.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.0/1199327.5 Hz   T2[0] : 0.0/1808.0 Hz   T3[0] :11.7/3520.8 Hz   T4[0] : 9.2/916.8 Hz   T5[0] :1763.0/1763.0 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.2/20479.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.0/1196735.8 Hz   T2[+] : 0.0/1798.4 Hz   T3[+] :11.7/3519.0 Hz   T4[+] : 9.2/917.4 Hz   T5[+] :1758.3/1758.3 Hz   T6[+] : 0.9/0.9  Hz   T7[+] :10.2/20483.0 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :11.9/1194971.4 Hz   T2[-] : 0.0/1792.0 Hz   T3[-] :11.7/3518.7 Hz   T4[-] : 9.1/914.9 Hz   T5[-] :1757.2/1757.2 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.2/20458.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   7957/795762007  T2[0] :      1/1199648  T3[0] :   7786/2336080  T4[0] :   6083/608331   T5[0] :1169753/1169753  T6[0] :    642/642      T7[0] :   6794/13588192  T8[0] :    663/679431   
    T1[+] :   3895/389515305  T2[+] :      0/585345   T3[+] :   3817/1145366  T4[+] :   2986/298603   T5[+] : 572307/572307   T6[+] :    306/306      T7[+] :   3333/6666852  T8[+] :    325/333293   
    T1[-] :   3889/388973691  T2[-] :      0/583313   T3[-] :   3817/1145382  T4[-] :   2978/297814   T5[-] : 571997/571997   T6[-] :    324/324      T7[-] :   3329/6659558  T8[-] :    325/333321   
    
    AVERAGE CURRENT
    BCM x1 : 29.2781uA  BCM x3 : 29.3369uA  BCM x10: 29.3169uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    560.9 ppm     BCM u3 :    542.8 ppm     BCM u10:    548.3 ppm     
    BCM d1 :    561.6 ppm     BCM d3 :    532.1 ppm     BCM d10:    542.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01895        BCM u3 [0]:0.01901        BCM u10[0]:0.01904        
    BCM u1 [+]:0.009297       BCM u3 [+]:0.009331       BCM u10[+]:0.009346       
    BCM u1 [-]:0.009288       BCM u3 [-]:0.009322       BCM u10[-]:0.009337       
    
    BCM d1 [0]:0.01991        BCM d3 [0]:0.01992        BCM d10[0]:0.01986        
    BCM d1 [+]:0.009769       BCM d3 [+]:0.009774       BCM d10[+]:0.009746       
    BCM d1 [-]:0.009759       BCM d3 [-]:0.009765       BCM d10[-]:0.009736       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3183 at Mon Feb 25 18:27:07 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.75977
    Left Arm Bottom VDC Current : -2.14844
    Left Arm Q1 power supply current : 2210.99
    Left Arm Q1 momentum : 2.93884
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.33
    Left Arm Q2 momentum :
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.7
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1169.99
    Left Arm Q3 momentum : 2.93882
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.9944
    Current on Unser monitor : 38.699
    Current on Upstream bcm : 29.8518
    Current on Downstream bcm : 30.1905
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.2588
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.97
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.0129736
    IPM1H04A.XPOS : 0.345454
    IPM1H04A.YPOS : 0.365886
    IPM1H04B.XPOS : 0.0573302
    IPM1H04B.YPOS : 1.65094
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.11377
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.081543
    HacL_alignROLL : 0.261391
    HacL_alignPITCH : -0.164359
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 435
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.358232
    Target OTR y-position : 2.12667
    Target OTR x-width : 0.889086
    Target OTR y-width : 0.970117
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.739596
    Arc OTR y-position : 0.272396
    Arc OTR x-width : 4.40261
    Arc OTR y-width : 3.54384
    Arc OTR data valid flag : No
    Arc OTR In/Out :
    Current Setpoint : 600
    Current Readback : 600.391