    Log entry time 19:09:28 on February 25, 2002

    Entry number 4224

    keyword=End_of_Run_3186
    ****************************
     Run Number: 3186
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e) production,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 322529       [+]: 157994       [-]: 157769       
    TIME  [0]: 3.811 mins  [+]: 1.871 mins  [-]: 1.870 mins  
    LIVE  [0]:  81.98%      [+]:  82.01%      [-]:  82.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :11.4/1137461.0 Hz   T2[0] : 0.0/1566.9 Hz   T3[0] :12.2/3669.6 Hz   T4[0] : 9.5/953.2 Hz   T5[0] :1674.9/1674.9 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.6/21274.7 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :11.3/1134740.0 Hz   T2[+] : 0.0/1557.6 Hz   T3[+] :12.2/3669.7 Hz   T4[+] : 9.5/948.0 Hz   T5[+] :1670.8/1670.8 Hz   T6[+] : 0.9/0.9  Hz   T7[+] :10.6/21276.8 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :11.3/1133664.0 Hz   T2[-] : 0.0/1554.1 Hz   T3[-] :12.2/3666.0 Hz   T4[-] : 9.6/957.5 Hz   T5[-] :1668.5/1668.5 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.6/21256.0 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2600/260080901  T2[0] :      0/358280   T3[0] :   2796/839064   T4[0] :   2179/217948   T5[0] : 382960/382960   T6[0] :    221/221      T7[0] :   2432/4864465  T8[0] :    228/234138   
    T1[+] :   1273/127355727  T2[+] :      0/174810   T3[+] :   1372/411858   T4[+] :   1063/106394   T5[+] : 187525/187525   T6[+] :    104/104      T7[+] :   1193/2387962  T8[+] :    112/114927   
    T1[-] :   1271/127178493  T2[-] :      0/174344   T3[-] :   1370/411264   T4[-] :   1074/107412   T5[-] : 187178/187178   T6[-] :    114/114      T7[-] :   1192/2384572  T8[-] :    112/114876   
    
    AVERAGE CURRENT
    BCM x1 : 30.4314uA  BCM x3 : 30.4937uA  BCM x10: 30.4722uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    371.1 ppm     BCM u3 :    345.5 ppm     BCM u10:    351.9 ppm     
    BCM d1 :      373 ppm     BCM d3 :    337.5 ppm     BCM d10:    346.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.006786       BCM u3 [0]:0.006811       BCM u10[0]:0.006822       
    BCM u1 [+]:0.003332       BCM u3 [+]:0.003344       BCM u10[+]:0.003349       
    BCM u1 [-]:0.003328       BCM u3 [-]:0.00334        BCM u10[-]:0.003346       
    
    BCM d1 [0]:0.00713        BCM d3 [0]:0.007133       BCM d10[0]:0.007113       
    BCM d1 [+]:0.003501       BCM d3 [+]:0.003502       BCM d10[+]:0.003492       
    BCM d1 [-]:0.003497       BCM d3 [-]:0.003498       BCM d10[-]:0.003488       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3186 at Mon Feb 25 19:09:23 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.125
    Left Arm Bottom VDC Current : 2.49023
    Left Arm Q1 power supply current : 2210.99
    Left Arm Q1 momentum : 2.93884
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.72
    Left Arm Q2 momentum : 2.93944
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.7
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.31
    Left Arm Q3 momentum : 2.9396
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.9669
    Current on Unser monitor : 39.1992
    Current on Upstream bcm : 29.8113
    Current on Downstream bcm : 30.1225
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.1892
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.97
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.000946939
    IPM1H04A.XPOS : 0.338548
    IPM1H04A.YPOS : 0.378866
    IPM1H04B.XPOS : 0.0894245
    IPM1H04B.YPOS : 1.65975
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.11377
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260657
    HacL_alignPITCH : -0.16451
    HacL_alignHPT :
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 433
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.356642
    Target OTR y-position : 2.12011
    Target OTR x-width : 0.879965
    Target OTR y-width : 0.96987
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.73744
    Arc OTR y-position : 0.278437
    Arc OTR x-width : 4.40293
    Arc OTR y-width : 3.54032
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407