• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:37:42 on February 26, 2002

    Entry number 4284

    keyword=End_of_Run_3218
    ****************************
     Run Number: 3218
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e) production 40 mkA,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 269802       [+]: 132265       [-]: 131851       
    TIME  [0]: 3.514 mins  [+]: 1.724 mins  [-]: 1.725 mins  
    LIVE  [0]:  84.02%      [+]:  84.10%      [-]:  84.02%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.7/865823.3 Hz   T2[0] : 0.0/897.2 Hz   T3[0] :16.5/4962.7 Hz   T4[0] :12.9/1295.0 Hz   T5[0] :1468.7/1468.7 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :14.2/28304.0 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 8.6/862896.8 Hz   T2[+] : 0.0/890.3 Hz   T3[+] :16.5/4959.3 Hz   T4[+] :12.9/1293.0 Hz   T5[+] :1466.3/1466.3 Hz   T6[+] : 1.1/1.1  Hz   T7[+] :14.1/28299.2 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 8.6/862690.0 Hz   T2[-] : 0.0/889.5 Hz   T3[-] :16.5/4958.9 Hz   T4[-] :12.9/1295.0 Hz   T5[-] :1462.2/1462.2 Hz   T6[-] : 0.9/0.9  Hz   T7[-] :14.1/28290.5 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1825/182561899  T2[0] :      0/189187   T3[0] :   3487/1046399  T4[0] :   2730/273060   T5[0] : 309689/309689   T6[0] :    205/205      T7[0] :   2984/5968005  T8[0] :    210/215914   
    T1[+] :    892/89248301  T2[+] :      0/92083    T3[+] :   1709/512932   T4[+] :   1337/133733   T5[+] : 151660/151660   T6[+] :    114/114      T7[+] :   1463/2926954  T8[+] :    103/105911   
    T1[-] :    892/89287572  T2[-] :      0/92062    T3[-] :   1710/513240   T4[-] :   1340/134031   T5[-] : 151336/151336   T6[-] :     91/91       T7[-] :   1464/2928042  T8[-] :    103/105983   
    
    AVERAGE CURRENT
    BCM x1 : 40.7726uA  BCM x3 : 40.8595uA  BCM x10: 40.7179uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    128.2 ppm     BCM u3 :    127.7 ppm     BCM u10:    124.7 ppm     
    BCM d1 :    131.5 ppm     BCM d3 :    128.2 ppm     BCM d10:    127.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.008383       BCM u3 [0]:0.008418       BCM u10[0]:0.008428       
    BCM u1 [+]:0.004112       BCM u3 [+]:0.004129       BCM u10[+]:0.004134       
    BCM u1 [-]:0.004114       BCM u3 [-]:0.004131       BCM u10[-]:0.004136       
    
    BCM d1 [0]:0.008811       BCM d3 [0]:0.008813       BCM d10[0]:0.008743       
    BCM d1 [+]:0.004322       BCM d3 [+]:0.004323       BCM d10[+]:0.004289       
    BCM d1 [-]:0.004324       BCM d3 [-]:0.004325       BCM d10[-]:0.00429        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3218 at Tue Feb 26 02:37:35 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.56445
    Left Arm Bottom VDC Current : 1.02539
    Left Arm Q1 power supply current : 2210.95
    Left Arm Q1 momentum : 2.9388
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.34
    Left Arm Q2 momentum : 2.93906
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.69
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.12
    Left Arm Q3 momentum : 2.93913
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 39.9753
    Current on Unser monitor : 47.6603
    Current on Upstream bcm : 39.5434
    Current on Downstream bcm : 39.9422
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 40.0499
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.87
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.00101554
    IPM1H04A.XPOS : 0.345321
    IPM1H04A.YPOS : 0.350715
    IPM1H04B.XPOS : 0.0587292
    IPM1H04B.YPOS : 1.63651
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : -0.0820312
    HacL_alignROLL : 0.261174
    HacL_alignPITCH : -0.164108
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 581
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.351652
    Target OTR y-position : 2.113
    Target OTR x-width : 0.890994
    Target OTR y-width : 0.969942
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.72297
    Arc OTR y-position : 0.279167
    Arc OTR x-width : 4.40343
    Arc OTR y-width : 3.54326
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391