Log entry time 20:34:13 on February 26, 2002
Entry number 4384
keyword=Start_Run_3264,Run_type=cosmics,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=test,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2R,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 3264 at Tue Feb 26 20:34:05 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=100000,ps2=10000000,ps3=1,ps4=100000,ps5=100000,ps6=100000,ps7=2000000,ps8=5555
Left Arm Q1 power supply current : 2210.99
Left Arm Q1 momentum : 2.93884
Left Arm Q1 gauss meter : 0.18737
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1265.79
Left Arm Q2 momentum : 2.9396
Left Arm Q2 gauss meter : -0.6663
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1026.7
Left Arm D1 momentum :
Left Arm D1 NMR : 1.08821
Left Arm Q3 power supply current : 1170.07
Left Arm Q3 momentum : 2.939
Left Arm Q3 gauss meter : 0.5857
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 0.390625
Left Arm Bottom VDC Current : 0.439453
Average current of the two cavities : 0.0290043
Current on Unser monitor : 7.58597
Current on Upstream bcm : 0.0327093
Current on Downstream bcm : 0.0252993
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5751.19
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3483.85
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 5768.48
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 0.0377197
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 869400
Arc1 dp/p : 3.06199e-05
Arc2 dp/p : -0.00157939
Left Arm Arm Collimator : 0.868604
HacL_HPE1313A:0_Ch58 : -0.112305
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.0795898
HacL_alignROLL : 0.263406
HacL_alignPITCH : -0.166017
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : 25.8
Left Arm Scattering Angle : 19.4697
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 60.4311
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1378.6
Wien field : 40.248
Laser attenuation Hall A : 220
Laser power Hall A : 71
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -0.761188
Arc OTR y-position : 0.303127
Arc OTR x-width : 4.40243
Arc OTR y-width : 3.5465
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.256352