• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:28:10 on February 27, 2002

    Entry number 4428

    keyword=End_of_Run_3284
    ****************************
     Run Number: 3284
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=Production run kinematics 3Ee. 40 muA,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=500   ps4=150   ps5=1   ps6=1   ps7=3000   ps8=1024   
    
    EVENTS[0]: 2002040      [+]: 978811       [-]: 980789       
    TIME  [0]: 32.096 mins  [+]: 15.747 mins  [-]: 15.747 mins  
    LIVE  [0]:  82.54%      [+]:  82.66%      [-]:  82.48%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 7.4/744855.0 Hz   T2[0] : 0.0/757.9 Hz   T3[0] : 8.4/4202.9 Hz   T4[0] : 7.3/1102.5 Hz   T5[0] :1227.3/1227.3 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.0/24010.6 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 7.4/741540.1 Hz   T2[+] : 0.0/750.1 Hz   T3[+] : 8.4/4194.7 Hz   T4[+] : 7.3/1101.7 Hz   T5[+] :1221.1/1221.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.0/23989.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 7.4/743035.4 Hz   T2[-] : 0.0/753.3 Hz   T3[-] : 8.4/4205.9 Hz   T4[-] : 7.3/1102.3 Hz   T5[-] :1226.4/1226.4 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.0/24019.6 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  14344/1434434342  T2[0] :      1/1459499  T3[0] :  16187/8093827  T4[0] :  14154/2123145  T5[0] :2363602/2363602  T6[0] :      0/0        T7[0] :  15413/46239393  T8[0] :   1925/1972009  
    T1[+] :   7006/700619972  T2[+] :      0/708682   T3[+] :   7926/3963237  T4[+] :   6939/1040876  T5[+] :1153740/1153740  T6[+] :      0/0        T7[+] :   7555/22665609  T8[+] :    944/967493   
    T1[-] :   7020/702024029  T2[-] :      0/711695   T3[-] :   7947/3973791  T4[-] :   6942/1041437  T5[-] :1158681/1158681  T6[-] :      0/0        T7[-] :   7564/22693866  T8[-] :    944/967481   
    
    AVERAGE CURRENT
    BCM x1 : 34.7475uA  BCM x3 : 34.8211uA  BCM x10: 34.7206uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -700.8 ppm     BCM u3 :   -689.7 ppm     BCM u10:   -699.5 ppm     
    BCM d1 :   -701.3 ppm     BCM d3 :   -677.9 ppm     BCM d10:   -671.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06525        BCM u3 [0]:0.06551        BCM u10[0]:0.0656         
    BCM u1 [+]:0.03198        BCM u3 [+]:0.03211        BCM u10[+]:0.03215        
    BCM u1 [-]:0.03203        BCM u3 [-]:0.03216        BCM u10[-]:0.0322         
    
    BCM d1 [0]:0.06858        BCM d3 [0]:0.0686         BCM d10[0]:0.06813        
    BCM d1 [+]:0.03361        BCM d3 [+]:0.03363        BCM d10[+]:0.0334         
    BCM d1 [-]:0.03366        BCM d3 [-]:0.03367        BCM d10[-]:0.03344        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3284 at Wed Feb 27 02:28:04 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.341797
    Left Arm Bottom VDC Current : 0.488281
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18745
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.73
    Left Arm Q2 momentum : 2.93946
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.7
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.01
    Left Arm Q3 momentum : 2.93886
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 38.5112
    Current on Unser monitor : 45.793
    Current on Upstream bcm : 38.3509
    Current on Downstream bcm : 38.6714
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 38.7036
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.89
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.00574498
    IPM1H04A.XPOS : 0.336433
    IPM1H04A.YPOS : 0.433525
    IPM1H04B.XPOS : 0.105219
    IPM1H04B.YPOS : 1.70913
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.112305
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260657
    HacL_alignPITCH : -0.165941
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 600
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.387105
    Target OTR y-position : 2.17641
    Target OTR x-width : 0.87195
    Target OTR y-width : 1.00236
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.745733
    Arc OTR y-position : 0.286768
    Arc OTR x-width : 4.3987
    Arc OTR y-width : 3.54257
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391