     Run Number: 3290
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=Production run kinematics 3Ee. 40 muA,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=500   ps4=150   ps5=1   ps6=1   ps7=3000   ps8=1024   
    
    EVENTS[0]: 2002441      [+]: 978784       [-]: 981887       
    TIME  [0]: 32.793 mins  [+]: 16.094 mins  [-]: 16.094 mins  
    LIVE  [0]:  83.96%      [+]:  84.04%      [-]:  83.96%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 7.2/724424.2 Hz   T2[0] : 0.0/669.1 Hz   T3[0] : 8.6/4310.8 Hz   T4[0] : 7.5/1128.3 Hz   T5[0] :1179.5/1179.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.2/24667.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 7.2/721185.1 Hz   T2[+] : 0.0/662.4 Hz   T3[+] : 8.6/4300.2 Hz   T4[+] : 7.5/1124.4 Hz   T5[+] :1173.6/1173.6 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.2/24633.8 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 7.2/722710.1 Hz   T2[-] : 0.0/664.8 Hz   T3[-] : 8.6/4316.7 Hz   T4[-] : 7.5/1131.2 Hz   T5[-] :1178.5/1178.5 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.2/24689.3 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  14253/1425365524  T2[0] :      1/1316548  T3[0] :  16963/8481788  T4[0] :  14800/2220037  T5[0] :2320820/2320820  T6[0] :      0/0        T7[0] :  16178/48535121  T8[0] :   1967/2014806  
    T1[+] :   6963/696383821  T2[+] :      0/639642   T3[+] :   8304/4152350  T4[+] :   7238/1085722  T5[+] :1133284/1133284  T6[+] :      0/0        T7[+] :   7928/23786632  T8[+] :    965/988785   
    T1[-] :   6978/697861986  T2[-] :      0/641914   T3[-] :   8336/4168314  T4[-] :   7282/1092300  T5[-] :1137960/1137960  T6[-] :      0/0        T7[-] :   7946/23840457  T8[-] :    965/988793   
    
    AVERAGE CURRENT
    BCM x1 : 35.5751uA  BCM x3 : 35.6519uA  BCM x10: 35.5703uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     -680 ppm     BCM u3 :   -666.7 ppm     BCM u10:   -677.4 ppm     
    BCM d1 :     -679 ppm     BCM d3 :   -654.2 ppm     BCM d10:     -654 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06826        BCM u3 [0]:0.06853        BCM u10[0]:0.06863        
    BCM u1 [+]:0.03347        BCM u3 [+]:0.0336         BCM u10[+]:0.03365        
    BCM u1 [-]:0.03351        BCM u3 [-]:0.03365        BCM u10[-]:0.0337         
    
    BCM d1 [0]:0.07174        BCM d3 [0]:0.07176        BCM d10[0]:0.07135        
    BCM d1 [+]:0.03518        BCM d3 [+]:0.03519        BCM d10[+]:0.03499        
    BCM d1 [-]:0.03522        BCM d3 [-]:0.03524        BCM d10[-]:0.03503        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3290 at Wed Feb 27 05:38:01 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -1.51367
    Left Arm Bottom VDC Current : 1.26953
    Left Arm Q1 power supply current : 2210.95
    Left Arm Q1 momentum : 2.9388
    Left Arm Q1 gauss meter : 0.18745
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.48
    Left Arm Q2 momentum : 2.93889
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.7
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.25
    Left Arm Q3 momentum : 2.93946
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 37.5934
    Current on Unser monitor : 45.9951
    Current on Upstream bcm : 37.4757
    Current on Downstream bcm : 37.9073
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 38.0191
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.04
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.0134298
    IPM1H04A.XPOS : 0.33429
    IPM1H04A.YPOS : 0.433664
    IPM1H04B.XPOS : 0.099007
    IPM1H04B.YPOS : 1.70727
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.081543
    HacL_alignROLL : 0.261616
    HacL_alignPITCH : -0.162677
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 600
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.389112
    Target OTR y-position : 2.17075
    Target OTR x-width : 0.874999
    Target OTR y-width : 1.00325
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.716082
    Arc OTR y-position : 0.271223
    Arc OTR x-width : 4.40853
    Arc OTR y-width : 3.5419
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391