    There were a couple items learned this shift.
    First, manually changing the fan settings can not, at present, be done via the target software, and attempts to do so may have unintended consequences. Don't even try. Newly trained target operators probably know this, so for some this may just be a reminder.
    Secondly, JP reminded us to BE PATIENT after a target IOC reboot. Sometimes it takes longer for the system to be restored, so just be patient. It might take as little as 3-4 minutes or as long as 10 minutes, and it is recommended you not try changing any settings for a couple minutes after it appears the reboot is complete.