• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:47:41 on February 28, 2002

    Entry number 4556

    keyword=End_of_Run_3335
    ****************************
     Run Number: 3335
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=Production run kinematics 3Ee. 40 muA. no bpm,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=500   ps4=150   ps5=1   ps6=1   ps7=3000   ps8=1024   
    
    EVENTS[0]: 2001397      [+]: 985218       [-]: 973527       
    TIME  [0]: 29.087 mins  [+]: 14.272 mins  [-]: 14.273 mins  
    LIVE  [0]:  82.68%      [+]:  82.62%      [-]:  82.82%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 7.9/791571.6 Hz   T2[0] : 0.0/762.4 Hz   T3[0] : 9.7/4859.1 Hz   T4[0] : 8.5/1272.6 Hz   T5[0] :1350.7/1350.7 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 9.2/27632.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 7.9/792211.4 Hz   T2[+] : 0.0/763.2 Hz   T3[+] : 9.7/4872.6 Hz   T4[+] : 8.5/1275.2 Hz   T5[+] :1356.1/1356.1 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 9.2/27705.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 7.9/785122.1 Hz   T2[-] : 0.0/748.5 Hz   T3[-] : 9.7/4838.2 Hz   T4[-] : 8.5/1268.6 Hz   T5[-] :1336.4/1336.4 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 9.2/27539.1 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  13814/1381461039  T2[0] :      1/1330514  T3[0] :  16960/8480191  T4[0] :  14806/2220959  T5[0] :2357335/2357335  T6[0] :      0/0        T7[0] :  16074/48223980  T8[0] :   1745/1787098  
    T1[+] :   6783/678387451  T2[+] :      0/653564   T3[+] :   8344/4172476  T4[+] :   7279/1091955  T5[+] :1161274/1161274  T6[+] :      0/0        T7[+] :   7908/23724489  T8[+] :    856/876873   
    T1[-] :   6723/672344400  T2[-] :      0/641021   T3[-] :   8286/4143197  T4[-] :   7242/1086400  T5[-] :1144477/1144477  T6[-] :      0/0        T7[-] :   7861/23583310  T8[-] :    856/876909   
    
    AVERAGE CURRENT
    BCM x1 : 40.1100uA  BCM x3 : 40.1986uA  BCM x10: 40.0588uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     3044 ppm     BCM u3 :     2965 ppm     BCM u10:     3006 ppm     
    BCM d1 :     3051 ppm     BCM d3 :     2911 ppm     BCM d10:     2870 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06826        BCM u3 [0]:0.06855        BCM u10[0]:0.06863        
    BCM u1 [+]:0.03358        BCM u3 [+]:0.03372        BCM u10[+]:0.03377        
    BCM u1 [-]:0.03338        BCM u3 [-]:0.03353        BCM u10[-]:0.03357        
    
    BCM d1 [0]:0.07174        BCM d3 [0]:0.07176        BCM d10[0]:0.07119        
    BCM d1 [+]:0.0353         BCM d3 [+]:0.03531        BCM d10[+]:0.03502        
    BCM d1 [-]:0.03508        BCM d3 [-]:0.0351         BCM d10[-]:0.03482        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3335 at Thu Feb 28 05:47:34 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3478.06
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -0.244141
    Left Arm Bottom VDC Current : -0.732422
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18745
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.67
    Left Arm Q2 momentum : 2.93932
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.7
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1169.93
    Left Arm Q3 momentum : 2.93865
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 39.8308
    Current on Unser monitor : 47.3389
    Current on Upstream bcm : 39.5601
    Current on Downstream bcm : 40.1015
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 39.9854
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3478.06
    Tiefenbach Hall C energy : 5752.16
    Delta(E)/E width (MV_AI_DXWID) : 1.31372
    IPM1C12.XPOS : 0.0099152
    IPM1H04A.XPOS : 0.33586
    IPM1H04A.YPOS : 0.433763
    IPM1H04B.XPOS : 0.110535
    IPM1H04B.YPOS : 1.71681
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : -0.0834961
    HacL_alignROLL : 0.25955
    HacL_alignPITCH : -0.163807
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 535
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.374162
    Target OTR y-position : 2.18447
    Target OTR x-width : 0.864998
    Target OTR y-width : 1.00414
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.713464
    Arc OTR y-position : 0.249109
    Arc OTR x-width : 4.409
    Arc OTR y-width : 3.54127
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407