User name a-onl
Log entry time 17:56:44 on February 28, 2002
Entry number 618
keyword=Start_Run_3362,Run_type=cosmics,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=cosmic run, restoration,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2R,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 3362 at Thu Feb 28 17:56:37 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=100000,ps2=1000000,ps3=1,ps4=150,ps5=1,ps6=1,ps7=3000,ps8=1024
Left Arm Q1 power supply current : 2242.87
Left Arm Q1 momentum : 2.98123
Left Arm Q1 gauss meter : 0.19005
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1283.71
Left Arm Q2 momentum : 2.9812
Left Arm Q2 gauss meter : -0.6757
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1043.08
Left Arm D1 momentum : 2.98101
Left Arm D1 NMR : 1.10379
Left Arm Q3 power supply current : 1436.83
Left Arm Q3 momentum : 3.60905
Left Arm Q3 gauss meter : 0.725
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -2.09961
Left Arm Bottom VDC Current : 1.85547
Average current of the two cavities : 0.0319827
Current on Unser monitor : 6.93782
Current on Upstream bcm : 0.0378473
Current on Downstream bcm : 0.0261181
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 40.0039
Tiefenbach Hall A energy : 3478.03
Tiefenbach Hall C energy : 5752.01
Delta(E)/E width (MV_AI_DXWID) : 10.0466
MBSY1c Hall A Beam energy : 3483.85
MBSY3c Hall C Beam energy : 5768.48
MBSY1c magnet current (amp) : 145.101
MBSY1c Bdl : 869400
Arc1 dp/p : 9.77344e-05
Arc2 dp/p : -0.00160927
Left Arm Arm Collimator : 0.868604
HacL_HPE1313A:0_Ch58 : -0.122559
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : -0.138672
HacL_alignROLL : 0.211791
HacL_alignPITCH : -0.134392
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 21.5
Left Arm Angle Vernier : 6.8
Left Arm Scattering Angle : 21.3602
IPM1C12.XPOS : -0.000273943
IPM1C12.YPOS : 0.0380422
IPM1H04A.XPOS : 0.32414
IPM1H04A.YPOS : 0.432442
IPM1H04B.XPOS : 0.0493204
IPM1H04B.YPOS : 1.73559
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 60.4311
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1378.6
Wien field : 40.248
Laser attenuation Hall A : 507
Laser power Hall A : 71
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 0.0243543
Target OTR y-position : 2.10484
Target OTR x-width : 0.233759
Target OTR y-width : 0.263937
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -0.730965
Arc OTR y-position : 0.271801
Arc OTR x-width : 4.41093
Arc OTR y-width : 3.54451
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286