User name a-onl
Log entry time 05:17:11 on March 1, 2002
Entry number 671
keyword=Start_Run_3385,Run_type=epcalib,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=3d ep calibration. no ped supression. also for fpp calib,daq_mode=coincidence,leftarm_p=2.981,leftarm_theta=21.36,photonarm_D=6.2,photonarm_angle=57,photonarm_p=500,target_name=lh2,target_type=15LH2
Beginning-of-run EPICS data for Run Number 3385 at Fri Mar 1 05:17:00 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=30000,ps2=1000000,ps3=40,ps4=20,ps5=1,ps6=1,ps7=700,ps8=1024
Left Arm Q1 power supply current : 2242.94
Left Arm Q1 momentum : 2.98132
Left Arm Q1 gauss meter : 0.19005
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1283.65
Left Arm Q2 momentum : 2.98108
Left Arm Q2 gauss meter : -0.6757
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1043.05
Left Arm D1 momentum : 2.98101
Left Arm D1 NMR : 1.10379
Left Arm Q3 power supply current : 1186.92
Left Arm Q3 momentum : 2.98132
Left Arm Q3 gauss meter : 0.5942
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -2.34375
Left Arm Bottom VDC Current : -1.5625
Average current of the two cavities : 40.0227
Current on Unser monitor : 46.858
Current on Upstream bcm : 39.6526
Current on Downstream bcm : 40.1124
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 40.3229
Tiefenbach Hall A energy : 3478.05
Tiefenbach Hall C energy : 5752.23
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3483.85
MBSY3c Hall C Beam energy : 5768.48
MBSY1c magnet current (amp) : 145.101
MBSY1c Bdl : 869400
Arc1 dp/p :
Arc2 dp/p :
Left Arm Arm Collimator : 0.868604
HacL_HPE1313A:0_Ch58 : -0.121094
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : -0.135742
HacL_alignROLL : 0.214735
HacL_alignPITCH : -0.135116
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 21.5
Left Arm Angle Vernier : 6.8
Left Arm Scattering Angle : 21.3602
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0.0354775
IPM1H04A.XPOS : 0.345924
IPM1H04A.YPOS : 0.441501
IPM1H04B.XPOS : 0.0908387
IPM1H04B.YPOS : 1.75667
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 60.4311
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1378.6
Wien field : 40.248
Laser attenuation Hall A : 538
Laser power Hall A : 71
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 0.384057
Target OTR y-position : 2.18146
Target OTR x-width : 0.871677
Target OTR y-width : 1.0072
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -0.739019
Arc OTR y-position : 0.28436
Arc OTR x-width : 4.40624
Arc OTR y-width : 3.54121
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286