    User name a-onl

    Log entry time 08:10:25 on March 1, 2002

    Entry number 685

    keyword=End_of_Run_3389
    ****************************
     Run Number: 3389
     End of Run Comment:
    Run_type=epcalib,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=3d ep calibration. no ped supression. also for fpp calib,daq_mode=coincidence,leftarm_p=2.981,leftarm_theta=21.36,photonarm_D=6.2,photonarm_angle=57,photonarm_p=500,target_name=lh2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=30000   ps2=1000000   ps3=40   ps4=20   ps5=1   ps6=1   ps7=700   ps8=1024   
    
    EVENTS[0]: 250767       [+]: 122893       [-]: 122526       
    TIME  [0]: 41.116 mins  [+]: 20.174 mins  [-]: 20.175 mins  
    LIVE  [0]:  93.12%      [+]:  93.11%      [-]:  93.13%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 5.3/160315.4 Hz   T2[0] : 0.0/46.3 Hz   T3[0] : 4.8/192.7 Hz   T4[0] : 5.9/118.8 Hz   T5[0] :86.4/86.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 5.7/3975.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 5.3/159961.5 Hz   T2[+] : 0.0/45.8 Hz   T3[+] : 4.8/192.6 Hz   T4[+] : 5.9/118.9 Hz   T5[+] :86.3/86.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 5.7/3976.8 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 5.3/159552.7 Hz   T2[-] : 0.0/45.8 Hz   T3[-] : 4.8/192.4 Hz   T4[-] : 5.9/118.6 Hz   T5[-] :86.0/86.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 5.7/3969.7 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  13183/395490784  T2[0] :      0/114205   T3[0] :  11882/475295   T4[0] :  14658/293168   T5[0] : 213083/213083   T6[0] :      0/0        T7[0] :  14008/9806286  T8[0] :   2466/2526162  
    T1[+] :   6454/193627639  T2[+] :      0/55466    T3[+] :   5827/233104   T4[+] :   7198/143977   T5[+] : 104426/104426   T6[+] :      0/0        T7[+] :   6876/4813717  T8[+] :   1210/1239515  
    T1[-] :   6437/193137456  T2[-] :      0/55483    T3[-] :   5821/232877   T4[-] :   7179/143586   T5[-] : 104049/104049   T6[-] :      0/0        T7[-] :   6864/4805265  T8[-] :   1210/1239545  
    
    AVERAGE CURRENT
    BCM x1 : 23.5018uA  BCM x3 : 23.5453uA  BCM x10: 23.4696uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1254 ppm     BCM u3 :     1222 ppm     BCM u10:     1237 ppm     
    BCM d1 :     1258 ppm     BCM d3 :     1202 ppm     BCM d10:     1183 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.05654        BCM u3 [0]:0.05673        BCM u10[0]:0.05681        
    BCM u1 [+]:0.02777        BCM u3 [+]:0.02786        BCM u10[+]:0.0279         
    BCM u1 [-]:0.0277         BCM u3 [-]:0.02779        BCM u10[-]:0.02783        
    
    BCM d1 [0]:0.05941        BCM d3 [0]:0.05945        BCM d10[0]:0.05899        
    BCM d1 [+]:0.02918        BCM d3 [+]:0.0292         BCM d10[+]:0.02897        
    BCM d1 [-]:0.02911        BCM d3 [-]:0.02913        BCM d10[-]:0.0289         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3389 at Fri Mar 1 08:10:13 EST 2002
    Left Arm D1 momentum : 2.98101
    Left Arm arm angle : 21.3602
    Tiefenbach Hall A energy : 3478.05
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.585938
    Left Arm Bottom VDC Current : 2.73438
    Left Arm Q1 power supply current : 2242.87
    Left Arm Q1 momentum : 2.98123
    Left Arm Q1 gauss meter : 0.19006
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1283.65
    Left Arm Q2 momentum : 2.98107
    Left Arm Q2 gauss meter : -0.6757
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1043.05
    Left Arm D1 momentum : 2.98101
    Left Arm D1 NMR : 1.10379
    Left Arm Q3 power supply current : 1187.17
    Left Arm Q3 momentum : 2.98194
    Left Arm Q3 gauss meter : 0.5942
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0310892
    Current on Unser monitor : 8.1739
    Current on Upstream bcm : 0.0355112
    Current on Downstream bcm : 0.0265975
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) :
    MBSY1c Hall A Beam energy :
    MBSY1c magnet current (amp) :
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3478.05
    Tiefenbach Hall C energy : 5752.03
    Delta(E)/E width (MV_AI_DXWID) : 11.4119
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.120605
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.134766
    HacL_alignROLL : 0.213917
    HacL_alignPITCH : -0.136362
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 200
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -0.749848
    Arc OTR y-position : 0.294365
    Arc OTR x-width : 4.40919
    Arc OTR y-width : 3.54711
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286