• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 01:48:37 on March 2, 2002

    Entry number 760

    keyword=End_of_Run_3418
    ****************************
     Run Number: 3418
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=3E Kinematics production LH2+R, magnet on,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=500,target_name=LH2+R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=80000   ps2=1000000   ps3=500   ps4=150   ps5=1   ps6=1   ps7=3000   ps8=1024   
    
    EVENTS[0]: 1901867      [+]: 931512       [-]: 928786       
    TIME  [0]: 27.749 mins  [+]: 13.611 mins  [-]: 13.612 mins  
    LIVE  [0]:  83.45%      [+]:  83.50%      [-]:  83.49%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.6/766897.9 Hz   T2[0] : 0.0/699.2 Hz   T3[0] : 9.9/4953.9 Hz   T4[0] : 8.7/1298.7 Hz   T5[0] :1330.4/1330.4 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 9.4/28321.3 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 9.6/765337.0 Hz   T2[+] : 0.0/694.6 Hz   T3[+] : 9.9/4954.0 Hz   T4[+] : 8.6/1297.2 Hz   T5[+] :1327.5/1327.5 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 9.4/28343.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 9.5/762386.7 Hz   T2[-] : 0.0/690.8 Hz   T3[-] : 9.9/4948.0 Hz   T4[-] : 8.7/1298.3 Hz   T5[-] :1323.7/1323.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 9.4/28279.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  15960/1276816771  T2[0] :      1/1164161  T3[0] :  16495/8247873  T4[0] :  14415/2162264  T5[0] :2214934/2214934  T6[0] :      0/0        T7[0] :  15717/47152502  T8[0] :   1664/1704869  
    T1[+] :   7812/625037457  T2[+] :      0/567273   T3[+] :   8091/4045839  T4[+] :   7062/1059418  T5[+] :1084152/1084152  T6[+] :      0/0        T7[+] :   7715/23147538  T8[+] :    816/836283   
    T1[-] :   7783/622640632  T2[-] :      0/564181   T3[-] :   8082/4041021  T4[-] :   7068/1060337  T5[-] :1081038/1081038  T6[-] :      0/0        T7[-] :   7698/23096151  T8[-] :    816/836300   
    
    AVERAGE CURRENT
    BCM x1 : 40.7902uA  BCM x3 : 40.8791uA  BCM x10: 40.7361uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1308 ppm     BCM u3 :     1274 ppm     BCM u10:     1292 ppm     
    BCM d1 :     1314 ppm     BCM d3 :     1250 ppm     BCM d10:     1233 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.06623        BCM u3 [0]:0.06651        BCM u10[0]:0.06659        
    BCM u1 [+]:0.03252        BCM u3 [+]:0.03266        BCM u10[+]:0.0327         
    BCM u1 [-]:0.03244        BCM u3 [-]:0.03258        BCM u10[-]:0.03262        
    
    BCM d1 [0]:0.06959        BCM d3 [0]:0.06961        BCM d10[0]:0.06905        
    BCM d1 [+]:0.03417        BCM d3 [+]:0.03418        BCM d10[+]:0.03391        
    BCM d1 [-]:0.03409        BCM d3 [-]:0.0341         BCM d10[-]:0.03382        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3418 at Sat Mar 2 01:48:30 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4703
    Tiefenbach Hall A energy : 3478.04
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.63672
    Left Arm Bottom VDC Current : -1.02539
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18749
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.54
    Left Arm Q2 momentum : 2.93902
    Left Arm Q2 gauss meter : -0.6664
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.59
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.11
    Left Arm Q3 momentum : 2.9391
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 40.038
    Current on Unser monitor : 46.9252
    Current on Upstream bcm : 39.8378
    Current on Downstream bcm : 40.2382
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 40.2904
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3478.04
    Tiefenbach Hall C energy : 5751.85
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0.288356
    IPM1H04A.YPOS : 0.432096
    IPM1H04B.XPOS : 0.0451367
    IPM1H04B.YPOS : 1.73347
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : -0.0708008
    HacL_alignROLL : 0.272159
    HacL_alignPITCH : -0.163556
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 543
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.318951
    Target OTR y-position : 2.19068
    Target OTR x-width : 0.858263
    Target OTR y-width : 1.00341
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.390821
    Arc OTR y-position : -0.502144
    Arc OTR x-width : 4.21333
    Arc OTR y-width : 3.6411
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391