• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:22:42 on March 3, 2002

    Entry number 890

    keyword=End_of_Run_3478
    ****************************
     Run Number: 3478
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=3A Kinematics production LH2+R, magnet off,daq_mode=coincidence,leftarm_p=1.254,leftarm_theta=45.658,photonarm_D=4.0,photonarm_angle=31,photonarm_p=390,target_name=LH2+R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=70000   ps2=1000000   ps3=35   ps4=15   ps5=1   ps6=1   ps7=250   ps8=1024   
    
    EVENTS[0]: 487520       [+]: 238693       [-]: 239171       
    TIME  [0]: 13.252 mins  [+]: 6.501 mins  [-]: 6.499 mins  
    LIVE  [0]:  86.18%      [+]:  86.15%      [-]:  86.23%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :23.0/1611256.0 Hz   T2[0] : 0.0/19.2 Hz   T3[0] :37.3/1305.0 Hz   T4[0] :29.3/439.3 Hz   T5[0] :610.2/610.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] :10.7/2684.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :22.9/1606479.4 Hz   T2[+] : 0.0/19.2 Hz   T3[+] :37.3/1303.9 Hz   T4[+] :29.3/439.5 Hz   T5[+] :609.2/609.2 Hz   T6[+] : 0.0/0.0  Hz   T7[+] :10.7/2683.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :23.0/1611210.1 Hz   T2[-] : 0.0/19.0 Hz   T3[-] :37.3/1304.8 Hz   T4[-] :29.3/438.8 Hz   T5[-] :610.0/610.0 Hz   T6[-] : 0.0/0.0  Hz   T7[-] :10.7/2685.6 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  18301/1281097988  T2[0] :      0/15270    T3[0] :  29646/1037628  T4[0] :  23285/349284   T5[0] : 485160/485160   T6[0] :      0/0        T7[0] :   8537/2134348  T8[0] :    795/814175   
    T1[+] :   8951/626575608  T2[+] :      0/7487     T3[+] :  14530/508568   T4[+] :  11427/171413   T5[+] : 237591/237591   T6[+] :      0/0        T7[+] :   4185/1046490  T8[+] :    390/399391   
    T1[-] :   8975/628293252  T2[-] :      0/7392     T3[-] :  14536/508793   T4[-] :  11407/171114   T5[-] : 237854/237854   T6[-] :      0/0        T7[-] :   4189/1047265  T8[-] :    389/399310   
    
    AVERAGE CURRENT
    BCM x1 : 3.0186 uA  BCM x3 : 3.0062 uA  BCM x10: 3.0139 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1249 ppm     BCM u3 :    -1278 ppm     BCM u10:    -1312 ppm     
    BCM d1 :    -1254 ppm     BCM d3 :    -1263 ppm     BCM d10:    -1300 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002371       BCM u3 [0]:0.002334       BCM u10[0]:0.002346       
    BCM u1 [+]:0.001161       BCM u3 [+]:0.001143       BCM u10[+]:0.001149       
    BCM u1 [-]:0.001164       BCM u3 [-]:0.001146       BCM u10[-]:0.001152       
    
    BCM d1 [0]:0.002429       BCM d3 [0]:0.002447       BCM d10[0]:0.002446       
    BCM d1 [+]:0.00119        BCM d3 [+]:0.001199       BCM d10[+]:0.001198       
    BCM d1 [-]:0.001193       BCM d3 [-]:0.001201       BCM d10[-]:0.001201       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3478 at Sun Mar 3 05:22:37 EST 2002
    Left Arm D1 momentum : 1.254
    Left Arm arm angle : 45.6582
    Tiefenbach Hall A energy : 3478.04
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.927734
    Left Arm Bottom VDC Current : -2.19727
    Left Arm Q1 power supply current : 943.145
    Left Arm Q1 momentum : 1.25363
    Left Arm Q1 gauss meter : 0.08053
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 540.154
    Left Arm Q2 momentum : 1.25442
    Left Arm Q2 gauss meter : -0.2848
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 418.647
    Left Arm D1 momentum : 1.254
    Left Arm D1 NMR : 0.46419
    Left Arm Q3 power supply current : 499.417
    Left Arm Q3 momentum : 1.25444
    Left Arm Q3 gauss meter : 0.25
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0285049
    Current on Unser monitor : 7.08664
    Current on Upstream bcm : 0.0319226
    Current on Downstream bcm : 0.0250872
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3478.04
    Tiefenbach Hall C energy : 5751.82
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00425094
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.265625
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : -0.362305
    HacL_alignROLL : 0.00806732
    HacL_alignPITCH : -0.00679319
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 300
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : 0.365793
    Arc OTR y-position : -0.522796
    Arc OTR x-width : 4.21644
    Arc OTR y-width : 3.64494
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.256352