    Log entry time 04:30:08 on March 4, 2002

    Entry number 994

    keyword=End_of_Run_3520
    ****************************
     Run Number: 3520
     End of Run Comment:
    Run_type=cosmics,beam_energy=1.203,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=DVCS Calorimeter calibration,daq_mode=L arm single,leftarm_p=1.132,leftarm_theta=18.001,photonarm_D=0.80,photonarm_angle=-62.3,photonarm_p=-,target_name=LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=100   ps2=99999   ps3=1   ps4=1   ps5=1   ps6=9999   ps7=9999   ps8=1024   
    
    EVENTS[0]: 852577       [+]: 417710       [-]: 418825       
    TIME  [0]: 6.911 mins  [+]: 3.390 mins  [-]: 3.391 mins  
    LIVE  [0]:  15.31%      [+]:  15.30%      [-]:  15.34%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :11.4/1144.6 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :6551.7/6551.7 Hz   T4[0] :6121.5/6121.5 Hz   T5[0] :742.0/742.0 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 1.1/11003.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :11.5/1148.0 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :6547.9/6547.9 Hz   T4[+] :6117.9/6117.9 Hz   T5[+] :744.8/744.8 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 1.1/10997.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :11.4/1140.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :6549.2/6549.2 Hz   T4[-] :6118.9/6118.9 Hz   T5[-] :738.7/738.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 1.1/11002.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   4746/474626   T2[0] :      0/0        T3[0] :2716759/2716759  T4[0] :2538351/2538351  T5[0] : 307672/307672   T6[0] :      0/0        T7[0] :    456/4562553  T8[0] :    414/424614   
    T1[+] :   2335/233541   T2[+] :      0/0        T3[+] :1332005/1332005  T4[+] :1244534/1244534  T5[+] : 151503/151503   T6[+] :      0/0        T7[+] :    223/2237150  T8[+] :    203/208307   
    T1[-] :   2320/232087   T2[-] :      0/0        T3[-] :1332527/1332527  T4[-] :1244981/1244981  T5[-] : 150299/150299   T6[-] :      0/0        T7[-] :    223/2238689  T8[-] :    203/208347   
    
    AVERAGE CURRENT
    BCM x1 : 1.0299 uA  BCM x3 : 1.0149 uA  BCM x10: 1.0224 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -652.7 ppm     BCM u3 :   -685.9 ppm     BCM u10:   -743.9 ppm     
    BCM d1 :   -464.4 ppm     BCM d3 :   -669.8 ppm     BCM d10:   -753.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0004305      BCM u3 [0]:0.0004102      BCM u10[0]:0.0004153      
    BCM u1 [+]:0.0002109      BCM u3 [+]:0.000201       BCM u10[+]:0.0002036      
    BCM u1 [-]:0.0002112      BCM u3 [-]:0.0002014      BCM u10[-]:0.0002039      
    
    BCM d1 [0]:0.0004236      BCM d3 [0]:0.0004316      BCM d10[0]:0.0004326      
    BCM d1 [+]:0.0002076      BCM d3 [+]:0.0002116      BCM d10[+]:0.0002121      
    BCM d1 [-]:0.0002078      BCM d3 [-]:0.0002119      BCM d10[-]:0.0002124      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3520 at Mon Mar 4 04:23:25 EST 2002
    Left Arm D1 momentum : 1.06542
    Left Arm arm angle : 26.0005
    Tiefenbach Hall A energy : 1201.87
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.15039
    Left Arm Bottom VDC Current : -2.14844
    Left Arm Q1 power supply current : 801.22
    Left Arm Q1 momentum : 1.06498
    Left Arm Q1 gauss meter : -0.0677
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 458.754
    Left Arm Q2 momentum : 1.06538
    Left Arm Q2 gauss meter : 0.2423
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 356.937
    Left Arm D1 momentum :
    Left Arm D1 NMR : 0.394434
    Left Arm Q3 power supply current : 200.193
    Left Arm Q3 momentum : 0.502467
    Left Arm Q3 gauss meter : -0.09972
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0313496
    Current on Unser monitor : 8.47273
    Current on Upstream bcm : 0.0375919
    Current on Downstream bcm : 0.0251073
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 1202.81
    MBSY1c magnet current (amp) : 49.8524
    MBSY1c Bdl : 300164
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 1201.87
    Tiefenbach Hall C energy : 5752.04
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868701
    HacL_HPE1313A:0_Ch58 : -0.145996
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.234375
    HacL_alignROLL : 0.124733
    HacL_alignPITCH : -0.113358
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 135
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) :
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.361333
    Arc OTR y-position : -0.52082
    Arc OTR x-width : 4.21383
    Arc OTR y-width : 3.63814
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0