• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:42:23 on March 4, 2002

    Entry number 1010

    keyword=End_of_Run_3527
    ****************************
     Run Number: 3527
     End of Run Comment:
    Run_type=epcalib,beam_energy=1.203,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=DVCS Calorimeter calibration (kinematics 5),daq_mode=L arm single,leftarm_p=977.43,leftarm_theta=35,photonarm_D=0.80,photonarm_angle=-62.3,photonarm_p=-,target_name=LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=5   ps2=99999   ps3=50   ps4=50   ps5=1   ps6=9999   ps7=9999   ps8=1024   
    
    EVENTS[0]: 176210       [+]: 86205        [-]: 86527        
    TIME  [0]: 15.512 mins  [+]: 7.608 mins  [-]: 7.609 mins  
    LIVE  [0]:  82.66%      [+]:  82.60%      [-]:  82.77%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :42.0/210.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :27.0/1352.3 Hz   T4[0] :24.6/1232.3 Hz   T5[0] :134.1/134.1 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.2/2416.3 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :42.0/210.0 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :27.0/1351.3 Hz   T4[+] :24.6/1231.4 Hz   T5[+] :133.8/133.8 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.2/2414.0 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :41.9/209.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :27.0/1351.6 Hz   T4[-] :24.6/1231.5 Hz   T5[-] :134.2/134.2 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.2/2416.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  39087/195439   T2[0] :      0/0        T3[0] :  25171/1258573  T4[0] :  22938/1146930  T5[0] : 124813/124813   T6[0] :      0/0        T7[0] :    224/2248847  T8[0] :    930/953029   
    T1[+] :  19170/95853    T2[+] :      0/0        T3[+] :  12336/616815   T4[+] :  11241/562095   T5[+] :  61054/61054    T6[+] :      0/0        T7[+] :    110/1101878  T8[+] :    456/467417   
    T1[-] :  19148/95741    T2[-] :      0/0        T3[-] :  12340/617008   T4[-] :  11244/562212   T5[-] :  61245/61245    T6[-] :      0/0        T7[-] :    110/1103123  T8[-] :    456/467467   
    
    AVERAGE CURRENT
    BCM x1 : 1.1516 uA  BCM x3 : 1.1396 uA  BCM x10: 1.1477 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -212.8 ppm     BCM u3 :   -363.4 ppm     BCM u10:   -382.7 ppm     
    BCM d1 :   -158.8 ppm     BCM d3 :   -331.6 ppm     BCM d10:   -381.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001076       BCM u3 [0]:0.001033       BCM u10[0]:0.001046       
    BCM u1 [+]:0.0005275      BCM u3 [+]:0.0005062      BCM u10[+]:0.0005125      
    BCM u1 [-]:0.0005277      BCM u3 [-]:0.0005066      BCM u10[-]:0.000513       
    
    BCM d1 [0]:0.001067       BCM d3 [0]:0.001089       BCM d10[0]:0.001091       
    BCM d1 [+]:0.000523       BCM d3 [+]:0.0005337      BCM d10[+]:0.0005347      
    BCM d1 [-]:0.0005232      BCM d3 [-]:0.0005341      BCM d10[-]:0.0005352      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3527 at Mon Mar 4 06:42:18 EST 2002
    Left Arm D1 momentum : 0.977431
    Left Arm arm angle : 35.0005
    Tiefenbach Hall A energy : 1201.87
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.244141
    Left Arm Bottom VDC Current : 1.80664
    Left Arm Q1 power supply current : 735
    Left Arm Q1 momentum : 0.976963
    Left Arm Q1 gauss meter : -0.06213
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 420.921
    Left Arm Q2 momentum : 0.977522
    Left Arm Q2 gauss meter : 0.2223
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 327.009
    Left Arm D1 momentum : 0.977431
    Left Arm D1 NMR : 0.361881
    Left Arm Q3 power supply current : 200.24
    Left Arm Q3 momentum : 0.502967
    Left Arm Q3 gauss meter : -0.09966
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 1.11461
    Current on Unser monitor : 8.71117
    Current on Upstream bcm : 1.10977
    Current on Downstream bcm : 1.11944
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 1.0487
    MBSY1c Hall A Beam energy : 1202.81
    MBSY1c magnet current (amp) : 49.8524
    MBSY1c Bdl : 300164
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 1201.87
    Tiefenbach Hall C energy : 5752.04
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00489435
    IPM1H04A.XPOS : -0.542323
    IPM1H04A.YPOS : -0.961484
    IPM1H04B.XPOS : -0.0468174
    IPM1H04B.YPOS : 1.92297
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.170898
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.253418
    HacL_alignROLL : 0.107142
    HacL_alignPITCH : -0.0903016
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 135
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.393166
    Arc OTR y-position : -0.530239
    Arc OTR x-width : 4.20401
    Arc OTR y-width : 3.6398
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0