• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 07:55:16 on March 4, 2002

    Entry number 1014

    keyword=End_of_Run_3528
    ****************************
     Run Number: 3528
     End of Run Comment:
    Run_type=epcalib,beam_energy=1.203,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=DVCS Calorimeter calibration (kinematics 5),daq_mode=L arm single,leftarm_p=977.43,leftarm_theta=35,photonarm_D=0.80,photonarm_angle=-62.3,photonarm_p=-,target_name=LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=5   ps2=99999   ps3=50   ps4=50   ps5=1   ps6=9999   ps7=9999   ps8=1024   
    
    EVENTS[0]: 1109491      [+]: 543198       [-]: 545364       
    TIME  [0]: 10.562 mins  [+]: 5.182 mins  [-]: 5.182 mins  
    LIVE  [0]:  16.32%      [+]:  16.30%      [-]:  16.35%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1954.2/9771.0 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :1022.2/51110.5 Hz   T4[0] :963.4/48172.0 Hz   T5[0] :6779.6/6779.6 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 8.2/81520.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :1952.4/9761.9 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :1021.3/51064.5 Hz   T4[+] :962.5/48126.9 Hz   T5[+] :6770.4/6770.4 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 8.1/81459.5 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :1954.7/9773.3 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :1022.2/51109.9 Hz   T4[-] :963.5/48174.9 Hz   T5[-] :6780.9/6780.9 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 8.2/81539.3 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1238420/6192104  T2[0] :      0/0        T3[0] : 647796/32389828  T4[0] : 610552/30527625  T5[0] :4296364/4296364  T6[0] :      0/0        T7[0] :   5166/51661059  T8[0] :    633/648931   
    T1[+] : 607042/3035211  T2[+] :      0/0        T3[+] : 317543/15877166  T4[+] : 299276/14963809  T5[+] :2105092/2105092  T6[+] :      0/0        T7[+] :   2533/25327689  T8[+] :    310/318386   
    T1[-] : 607776/3038880  T2[-] :      0/0        T3[-] : 317838/15891922  T4[-] : 299586/14979337  T5[-] :2108424/2108424  T6[-] :      0/0        T7[-] :   2535/25353558  T8[-] :    310/318399   
    
    AVERAGE CURRENT
    BCM x1 : 1.1198 uA  BCM x3 : 1.1068 uA  BCM x10: 1.1148 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -156.7 ppm     BCM u3 :   -229.5 ppm     BCM u10:     -261 ppm     
    BCM d1 :   -123.3 ppm     BCM d3 :   -196.5 ppm     BCM d10:   -271.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0007136      BCM u3 [0]:0.0006833      BCM u10[0]:0.0006919      
    BCM u1 [+]:0.0003499      BCM u3 [+]:0.0003352      BCM u10[+]:0.0003394      
    BCM u1 [-]:0.00035        BCM u3 [-]:0.0003353      BCM u10[-]:0.0003396      
    
    BCM d1 [0]:0.0007056      BCM d3 [0]:0.0007195      BCM d10[0]:0.000721       
    BCM d1 [+]:0.000346       BCM d3 [+]:0.0003529      BCM d10[+]:0.0003536      
    BCM d1 [-]:0.0003461      BCM d3 [-]:0.0003531      BCM d10[-]:0.0003538      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3528 at Mon Mar 4 07:55:11 EST 2002
    Left Arm D1 momentum : 1.13229
    Left Arm arm angle : 18.0005
    Tiefenbach Hall A energy : 1201.87
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -8.78906
    Left Arm Bottom VDC Current : -2.49023
    Left Arm Q1 power supply current : 851.69
    Left Arm Q1 momentum : 1.13207
    Left Arm Q1 gauss meter : -0.07194
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 487.346
    Left Arm Q2 momentum : 1.13178
    Left Arm Q2 gauss meter : 0.2575
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 379.567
    Left Arm D1 momentum : 1.13229
    Left Arm D1 NMR : 0.419181
    Left Arm Q3 power supply current : 199.822
    Left Arm Q3 momentum : 0.501916
    Left Arm Q3 gauss meter : -0.09969
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 1.13822
    Current on Unser monitor : 8.32517
    Current on Upstream bcm : 1.13413
    Current on Downstream bcm : 1.14068
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 1.07338
    MBSY1c Hall A Beam energy : 1202.81
    MBSY1c magnet current (amp) : 49.8524
    MBSY1c Bdl : 300164
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 1201.86
    Tiefenbach Hall C energy : 5752.04
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.00745466
    IPM1H04A.XPOS : -0.565203
    IPM1H04A.YPOS : -0.942648
    IPM1H04B.XPOS : -0.0445272
    IPM1H04B.YPOS : 1.94282
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.152832
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.0078125
    HacL_alignROLL : 0.332115
    HacL_alignPITCH : -0.127205
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 135
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.364808
    Arc OTR y-position : -0.52743
    Arc OTR x-width : 4.21513
    Arc OTR y-width : 3.64217
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0