• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 08:51:57 on March 4, 2002

    Entry number 1021

    keyword=End_of_Run_3530
    ****************************
     Run Number: 3530
     End of Run Comment:
    Run_type=epcalib,beam_energy=1.203,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=DVCS Calorimeter calibration (kinematics 2),daq_mode=L arm single,leftarm_p=1100.73,leftarm_theta=22,photonarm_D=0.80,photonarm_angle=-62.3,photonarm_p=-,target_name=LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=5   ps2=99999   ps3=50   ps4=50   ps5=1   ps6=9999   ps7=9999   ps8=1024   
    
    EVENTS[0]: 1926749      [+]: 945656       [-]: 944640       
    TIME  [0]: 17.546 mins  [+]: 8.610 mins  [-]: 8.610 mins  
    LIVE  [0]:  51.44%      [+]:  51.45%      [-]:  51.45%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :662.4/3312.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :357.7/17886.5 Hz   T4[0] :335.2/16758.2 Hz   T5[0] :2198.9/2198.9 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 2.9/29334.5 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :662.7/3313.5 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :357.5/17874.2 Hz   T4[+] :335.0/16748.5 Hz   T5[+] :2199.2/2199.2 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 2.9/29324.6 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :661.7/3308.5 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :357.7/17885.3 Hz   T4[-] :335.1/16755.8 Hz   T5[-] :2195.7/2195.7 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 2.9/29332.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 697410/3487050  T2[0] :      0/0        T3[0] : 376610/18830548  T4[0] : 352855/17642754  T5[0] :2314910/2314910  T6[0] :      0/0        T7[0] :   3088/30882750  T8[0] :   1052/1078047  
    T1[+] : 342340/1711700  T2[+] :      0/0        T3[+] : 184671/9233575  T4[+] : 173041/8652074  T5[+] :1136094/1136094  T6[+] :      0/0        T7[+] :   1515/15148729  T8[+] :    516/528986   
    T1[-] : 341822/1709110  T2[-] :      0/0        T3[-] : 184783/9239187  T4[-] : 173114/8655707  T5[-] :1134260/1134260  T6[-] :      0/0        T7[-] :   1515/15152554  T8[-] :    516/528979   
    
    AVERAGE CURRENT
    BCM x1 : 1.1212 uA  BCM x3 : 1.1082 uA  BCM x10: 1.1161 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    261.4 ppm     BCM u3 :    57.07 ppm     BCM u10:    42.78 ppm     
    BCM d1 :    276.3 ppm     BCM d3 :    93.95 ppm     BCM d10:    49.33 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001187       BCM u3 [0]:0.001136       BCM u10[0]:0.001151       
    BCM u1 [+]:0.0005821      BCM u3 [+]:0.0005576      BCM u10[+]:0.0005646      
    BCM u1 [-]:0.0005818      BCM u3 [-]:0.0005575      BCM u10[-]:0.0005645      
    
    BCM d1 [0]:0.001174       BCM d3 [0]:0.001197       BCM d10[0]:0.001199       
    BCM d1 [+]:0.000576       BCM d3 [+]:0.0005873      BCM d10[+]:0.0005885      
    BCM d1 [-]:0.0005756      BCM d3 [-]:0.0005872      BCM d10[-]:0.0005885      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3530 at Mon Mar 4 08:51:52 EST 2002
    Left Arm D1 momentum : 1.10073
    Left Arm arm angle : 22.0005
    Tiefenbach Hall A energy : 1201.87
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.146484
    Left Arm Bottom VDC Current : -0.0976562
    Left Arm Q1 power supply current : 827.89
    Left Arm Q1 momentum : 1.10043
    Left Arm Q1 gauss meter : -0.06993
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 473.882
    Left Arm Q2 momentum : 1.10052
    Left Arm Q2 gauss meter : 0.2503
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 368.803
    Left Arm D1 momentum : 1.10073
    Left Arm D1 NMR : 0.407498
    Left Arm Q3 power supply current : 199.931
    Left Arm Q3 momentum : 0.50219
    Left Arm Q3 gauss meter : -0.0997
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 1.13723
    Current on Unser monitor : 9.01244
    Current on Upstream bcm : 1.1307
    Current on Downstream bcm : 1.14376
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 1.07054
    MBSY1c Hall A Beam energy : 1202.81
    MBSY1c magnet current (amp) : 49.8524
    MBSY1c Bdl : 300164
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 1201.88
    Tiefenbach Hall C energy : 5752.04
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.0124035
    IPM1H04A.XPOS : -0.536427
    IPM1H04A.YPOS : -0.946623
    IPM1H04B.XPOS : -0.0347239
    IPM1H04B.YPOS : 1.94186
    Left Arm Arm Collimator : 0.868701
    HacL_HPE1313A:0_Ch58 : -0.119629
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.125
    HacL_alignROLL : 0.221791
    HacL_alignPITCH : -0.136712
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868652
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 135
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.425376
    Arc OTR y-position : -0.525313
    Arc OTR x-width : 4.21082
    Arc OTR y-width : 3.64277
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0