User name a-onl
Log entry time 18:43:34 on March 4, 2002
Entry number 1024
keyword=Start_Run_3531,Run_type=other,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=5 pass calibration of proton array,daq_mode=L arm single,leftarm_p=3.471,leftarm_theta=14.7,photonarm_D=-,photonarm_angle=-,photonarm_p=-,target_name=LH2,target_type=15LH2
Beginning-of-run EPICS data for Run Number 3531 at Mon Mar 4 18:43:27 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the DVCS calorimeter singles based on OR of 9 blocks
; PS2 irrelevant
; PS3 for the Left spectrometer based on T3 defined by S0
; PS4 for the Left spectrometer redundant trigger S1 and S0
; PS6 for coincidence of T1 and T3.
; PS7 irrelevant
; PS8 for pulser
ps1=5,ps2=99999,ps3=50,ps4=50,ps5=1,ps6=9999,ps7=9999,ps8=1024
Left Arm Q1 power supply current : 2611.28
Left Arm Q1 momentum : 3.47092
Left Arm Q1 gauss meter : -0.22067
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1494.8
Left Arm Q2 momentum : 3.47145
Left Arm Q2 gauss meter : 0.7866
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1240.62
Left Arm D1 momentum : 3.47101
Left Arm D1 NMR : 1.28562
Left Arm Q3 power supply current : 1381.88
Left Arm Q3 momentum : 3.47102
Left Arm Q3 gauss meter : -0.6911
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : 4.44336
Left Arm Bottom VDC Current : 2.44141
Average current of the two cavities : 0.481915
Current on Unser monitor : 8.61561
Current on Upstream bcm : 0.479737
Current on Downstream bcm : 0.484092
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.880748
Tiefenbach Hall A energy : 5751.66
Tiefenbach Hall C energy : 1201.85
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 5765.78
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1204.48
MBSY1c magnet current (amp) : 241.034
MBSY1c Bdl : 1.43886e+06
Arc1 dp/p : 5.70256e-05
Arc2 dp/p : -0.00155663
Left Arm Arm Collimator : 0.868652
HacL_HPE1313A:0_Ch58 : -0.18457
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : 0.0717773
HacL_alignROLL : 0.408532
HacL_alignPITCH : -0.098187
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : -21
Left Arm Scattering Angle : 14.7
IPM1C12.XPOS : 0.540383
IPM1C12.YPOS : -0.183199
IPM1H04A.XPOS : 0.989748
IPM1H04A.YPOS : 1.34593
IPM1H04B.XPOS : 0.0687755
IPM1H04B.YPOS : 1.76463
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 96.2504
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 2234.6
Wien field : 64.166
Laser attenuation Hall A : 115
Laser power Hall A : 71
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 0.443349
Arc OTR y-position : -0.52188
Arc OTR x-width : 4.2043
Arc OTR y-width : 3.63483
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0