    User name a-onl

    Log entry time 16:14:03 on March 9, 2002

    Entry number 1261

    keyword=Start_Run_4037,Run_type=cosmics,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Detector tests cosmics without beam on empty target,daq_mode=coincidence,leftarm_p=1.97,leftarm_theta=20.69,photonarm_D=hrs,photonarm_angle=18.6,photonarm_p=3.145,target_name=empty,target_type=Empty
    Beginning-of-run EPICS data for Run Number 4037 at Sat Mar 9 16:13:58 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1*S0+S2*S0
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
     
    Left Arm Q1 power supply current : 1482.11
    Left Arm Q1 momentum : 1.97002
    Left Arm Q1 gauss meter : 0.12582
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 848.618
    Left Arm Q2 momentum : 1.97078
    Left Arm Q2 gauss meter : -0.4469
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 668.305
    Left Arm D1 momentum : 1.97
    Left Arm D1 NMR : 0.728977
    Left Arm Q3 power supply current : 784.305
    Left Arm Q3 momentum : 1.97003
    Left Arm Q3 gauss meter : 0.3927
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : -0.78125
    Left Arm Bottom VDC Current : -2.19727
    Average current of the two cavities : 94.9864
    Current on Unser monitor : 100.511
    Current on Upstream bcm : 93.8313
    Current on Downstream bcm : 96.1415
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 94.815
    Tiefenbach Hall A energy : 5753.78
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5765.77
    MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1204.48
    MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 241.034
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1.43885e+06
    Arc1 dp/p : 8.86898e-05
    Arc2 dp/p : -0.00125051
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.129883
    HacL_HPE1313A:0_Ch55 : 24.707
    HacL_HPE1313A:0_Ch54 : -0.168945
    HacL_alignROLL : 0.186892
    HacL_alignPITCH : -0.130814
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 21
    Left Arm Angle Vernier : -22.8
    Left Arm Scattering Angle : 20.6896
    IPM1C12.XPOS : 1.62125e-05
    IPM1C12.YPOS : 0.0389024
    IPM1H04A.XPOS : 0.535384
    IPM1H04A.YPOS : 0.174153
    IPM1H04B.XPOS : -1.99975
    IPM1H04B.YPOS : -0.343199
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 96.2504
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.166
    Laser attenuation Hall A : 402
    Laser power Hall A : 70
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -1.55956
    Target OTR y-position : -0.0964747
    Target OTR x-width : 0.162174
    Target OTR y-width : 0.213553
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -0.676534
    Arc OTR y-position : 0.33134
    Arc OTR x-width : 4.39844
    Arc OTR y-width : 3.54119
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0