• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:08:02 on March 10, 2002

    Entry number 1417

    keyword=End_of_Run_4104
    ****************************
     Run Number: 4104
     End of Run Comment:
    Run_type=production,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=kin11; 4 cm LH2,daq_mode=coincidence,leftarm_p=1.97,leftarm_theta=20.69,photonarm_D=hrs,photonarm_angle=18.6,photonarm_p=3.145,target_name=4 cm LH2,target_type=15LH2R
     Problems with the machine, many trips.
    
    PRESCALE FACTORS:ps1=1200   ps2=100   ps3=15000   ps4=750   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 282450       [+]: 138819       [-]: 138368       
    TIME  [0]: 167.373 mins  [+]: 82.128 mins  [-]: 82.132 mins  
    LIVE  [0]:  99.60%      [+]:  99.45%      [-]:  99.74%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 1.7/2081.3 Hz   T2[0] : 1.9/189.4 Hz   T3[0] : 1.2/18690.1 Hz   T4[0] : 1.2/881.3 Hz   T5[0] :22.2/22.2 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 1.7/2081.5 Hz   T2[+] : 1.9/189.4 Hz   T3[+] : 1.2/18694.0 Hz   T4[+] : 1.2/881.5 Hz   T5[+] :22.3/22.3 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 1.7/2081.5 Hz   T2[-] : 1.9/189.5 Hz   T3[-] : 1.2/18691.2 Hz   T4[-] : 1.2/881.3 Hz   T5[-] :22.1/22.1 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  17418/20901629  T2[0] :  19022/1902246  T3[0] :  12512/187693690  T4[0] :  11800/8850348  T5[0] : 222675/222675   T6[0] :      0/0        T7[0] :      0/0        T8[0] :    156/10283405  
    T1[+] :   8547/10256918  T2[+] :   9334/933408   T3[+] :   6141/92117593  T4[+] :   5791/4343621  T5[+] : 109704/109704   T6[+] :      0/0        T7[+] :      0/0        T8[+] :     76/5045915  
    T1[-] :   8547/10257575  T2[-] :   9338/933822   T3[-] :   6140/92108683  T4[-] :   5790/4343020  T5[-] : 108833/108833   T6[-] :      0/0        T7[-] :      0/0        T8[-] :     77/5046195  
    
    AVERAGE CURRENT
    BCM x1 : 24.9864uA  BCM x3 : 12.3073uA  BCM x10: -14.9484uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    189.2 ppm     BCM u3 :    178.3 ppm     BCM u10:    26.19 ppm     
    BCM d1 :    191.3 ppm     BCM d3 :    1E+39 ppm     BCM d10:   -67.84 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.2466         BCM u3 [0]:0.2474         BCM u10[0]:-0.1314        
    BCM u1 [+]:0.1211         BCM u3 [+]:0.1214         BCM u10[+]:0.1039         
    BCM u1 [-]:0.121          BCM u3 [-]:0.1214         BCM u10[-]:0.1039         
    
    BCM d1 [0]:0.2552         BCM d3 [0]:-0.0002267     BCM d10[0]:-0.1688        
    BCM d1 [+]:0.1253         BCM d3 [+]:-0.0001113     BCM d10[+]:0.08273        
    BCM d1 [-]:0.1252         BCM d3 [-]:-0.0001111     BCM d10[-]:0.08275        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4104 at Sun Mar 10 18:07:56 EST 2002
    Left Arm D1 momentum : 1.97001
    Left Arm arm angle : 20.6896
    Tiefenbach Hall A energy : 5752.58
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.49023
    Left Arm Bottom VDC Current : 2.44141
    Left Arm Q1 power supply current : 1482.25
    Left Arm Q1 momentum : 1.97021
    Left Arm Q1 gauss meter : 0.12587
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 848.257
    Left Arm Q2 momentum : 1.96994
    Left Arm Q2 gauss meter : -0.4471
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 668.36
    Left Arm D1 momentum : 1.97001
    Left Arm D1 NMR : 0.728977
    Left Arm Q3 power supply current : 784.36
    Left Arm Q3 momentum : 1.97017
    Left Arm Q3 gauss meter : 0.3927
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0324049
    Current on Unser monitor : 8.51646
    Current on Upstream bcm : 0.0364696
    Current on Downstream bcm : 0.0283402
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 94.6873
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5752.58
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.144043
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.180176
    HacL_alignROLL : 0.174975
    HacL_alignPITCH : -0.115936
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.2504
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.166
    Laser attenuation Hall A : 390
    Laser power Hall A : 70
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.435784
    Arc OTR y-position : -0.518919
    Arc OTR x-width : 4.19911
    Arc OTR y-width : 3.6447
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0