• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:10:45 on March 11, 2002

    Entry number 1467

    keyword=End_of_Run_4118
    ****************************
     Run Number: 4118
     End of Run Comment:
    Run_type=production,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=kin12; optics target,daq_mode=coincidence,leftarm_p=2.147,leftarm_theta=19.30,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=optics,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 1008556      [+]: 495271       [-]: 494439       
    TIME  [0]: 6.860 mins  [+]: 3.366 mins  [-]: 3.365 mins  
    LIVE  [0]:  53.20%      [+]:  53.21%      [-]:  53.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :472.3/472.3 Hz   T2[0] :70.8/70.8 Hz   T3[0] :3867.4/3867.4 Hz   T4[0] :191.6/191.6 Hz   T5[0] : 3.7/3.7  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :471.5/471.5 Hz   T2[+] :70.8/70.8 Hz   T3[+] :3870.6/3870.6 Hz   T4[+] :192.7/192.7 Hz   T5[+] : 3.8/3.8  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :472.9/472.9 Hz   T2[-] :70.8/70.8 Hz   T3[-] :3864.4/3864.4 Hz   T4[-] :190.7/190.7 Hz   T5[-] : 3.6/3.6  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 194415/194415   T2[0] :  29148/29148    T3[0] :1591901/1591901  T4[0] :  78877/78877    T5[0] :   1519/1519     T6[0] :      0/0        T7[0] :      0/0        T8[0] :      6/421498   
    T1[+] :  95217/95217    T2[+] :  14291/14291    T3[+] : 781652/781652   T4[+] :  38905/38905    T5[+] :    770/770      T6[+] :      0/0        T7[+] :      0/0        T8[+] :      3/206790   
    T1[-] :  95493/95493    T2[-] :  14302/14302    T3[-] : 780268/780268   T4[-] :  38499/38499    T5[-] :    722/722      T6[-] :      0/0        T7[-] :      0/0        T8[-] :      3/206756   
    
    AVERAGE CURRENT
    BCM x1 : 9.9158 uA  BCM x3 : 4.8445 uA  BCM x10: 9.9355 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     93.7 ppm     BCM u3 :    67.07 ppm     BCM u10:     58.3 ppm     
    BCM d1 :     76.7 ppm     BCM d3 :    1E+39 ppm     BCM d10:     56.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.003996       BCM u3 [0]:0.003997       BCM u10[0]:0.004008       
    BCM u1 [+]:0.00196        BCM u3 [+]:0.001961       BCM u10[+]:0.001967       
    BCM u1 [-]:0.00196        BCM u3 [-]:0.001961       BCM u10[-]:0.001966       
    
    BCM d1 [0]:0.004168       BCM d3 [0]:-9.294E-06     BCM d10[0]:0.004171       
    BCM d1 [+]:0.002045       BCM d3 [+]:-4.563E-06     BCM d10[+]:0.002047       
    BCM d1 [-]:0.002044       BCM d3 [-]:-4.554E-06     BCM d10[-]:0.002046       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4118 at Mon Mar 11 19:10:38 EST 2002
    Left Arm D1 momentum : 2.14699
    Left Arm arm angle : 19.2979
    Tiefenbach Hall A energy : 5753.66
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.05078
    Left Arm Bottom VDC Current : -2.05078
    Left Arm Q1 power supply current : 1615.29
    Left Arm Q1 momentum : 2.14704
    Left Arm Q1 gauss meter : 0.13711
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 924.522
    Left Arm Q2 momentum : 2.14706
    Left Arm Q2 gauss meter : -0.4873
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 732.355
    Left Arm D1 momentum : 2.147
    Left Arm D1 NMR : 0.794432
    Left Arm Q3 power supply current : 854.763
    Left Arm Q3 momentum : 2.14701
    Left Arm Q3 gauss meter : 0.4279
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.033052
    Current on Unser monitor : 6.39565
    Current on Upstream bcm : 0.0381678
    Current on Downstream bcm : 0.0279362
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.66
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 3.28529
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.12793
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : -0.132812
    HacL_alignROLL : 0.216944
    HacL_alignPITCH : -0.129889
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.2504
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.166
    Laser attenuation Hall A : 100
    Laser power Hall A : 70
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.336063
    Arc OTR y-position : -0.496134
    Arc OTR x-width : 4.22148
    Arc OTR y-width : 3.64697
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0