Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 13:32:00 on March 12, 2002
Entry number 1534
keyword=Start_Run_4145,Run_type=production,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=further junk to test rhe rich daq,daq_mode=coincidence,leftarm_p=2.147,leftarm_theta=19.30,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=15cm LH2,target_type=15LH2
Beginning-of-run EPICS data for Run Number 4145 at Tue Mar 12 13:31:45 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the Right spectrometer based on T1 defined by S1*S2
; PS2 for the Right spectrometer based on T2 defined by S1*S0+S2*S0
; PS3 for the Left spectrometer based on T3 defined by S1*S2
; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
; PS5 for coincidence of T1 and T3.
; PS7 irrelevant
; PS8 for pulser
ps1=100000,ps2=100000,ps3=1,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 power supply current : 1615.29
Left Arm Q1 momentum : 2.14704
Left Arm Q1 gauss meter : 0.13707
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 924.286
Left Arm Q2 momentum : 2.14651
Left Arm Q2 gauss meter : -0.4871
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 732.335
Left Arm D1 momentum : 2.14699
Left Arm D1 NMR : 0.794427
Left Arm Q3 power supply current : 854.706
Left Arm Q3 momentum : 2.14686
Left Arm Q3 gauss meter : 0.4278
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 0.488281
Left Arm Bottom VDC Current : 0.585938
Average current of the two cavities : 0.0358839
Current on Unser monitor : 8.76407
Current on Upstream bcm : 0.0414585
Current on Downstream bcm : 0.0303093
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5753.53
Tiefenbach Hall C energy : 1201.48
Delta(E)/E width (MV_AI_DXWID) : 4.22755
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5765.77
MBSY3c Hall C Beam energy : 1204.48
MBSY1c magnet current (amp) : 241.034
MBSY1c Bdl : 1.43885e+06
Arc1 dp/p : 7.09752e-06
Arc2 dp/p : -0.00158935
Left Arm Arm Collimator : 0.616895
HacL_HPE1313A:0_Ch58 : -0.122559
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.131348
HacL_alignROLL : 0.217386
HacL_alignPITCH : -0.135127
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -4
Left Arm Scattering Angle : 19.2979
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS :
IPM1H04A.YPOS :
IPM1H04B.XPOS :
IPM1H04B.YPOS :
Survey X offset bpmA :
Survey Y offset bpmA :
Survey X offset bpmB :
Survey Y offset bpmB :
Wien angle : 96.2504
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 2234.6
Wien field : 64.166
Laser attenuation Hall A : 600
Laser power Hall A : 63
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 0.39757
Arc OTR y-position : -0.49611
Arc OTR x-width : 4.21366
Arc OTR y-width : 3.64364
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0