• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:27:44 on March 14, 2002

    Entry number 1651

    keyword=End_of_Run_4181
    ****************************
     Run Number: 4181
     End of Run Comment:
    Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Kinematics 15, multifoil carbon target, with rich, HV 1550V Ar/CH4,daq_mode=coincidence,leftarm_p=2.060,leftarm_theta=26.167,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=15cm LH2,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 1002804      [+]: 492183       [-]: 492271       
    TIME  [0]: 12.344 mins  [+]: 6.059 mins  [-]: 6.059 mins  
    LIVE  [0]:  73.91%      [+]:  73.95%      [-]:  73.89%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :495.7/495.7 Hz   T2[0] :71.8/71.8 Hz   T3[0] :1180.2/1180.2 Hz   T4[0] :80.7/80.7 Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/0.8  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :494.7/494.7 Hz   T2[+] :72.0/72.0 Hz   T3[+] :1179.9/1179.9 Hz   T4[+] :81.0/81.0 Hz   T5[+] : 3.3/3.3  Hz   T6[+] : 0.0/0.8  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :496.0/496.0 Hz   T2[-] :71.8/71.8 Hz   T3[-] :1180.6/1180.6 Hz   T4[-] :80.5/80.5 Hz   T5[-] : 3.5/3.5  Hz   T6[-] : 0.0/0.8  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 367111/367111   T2[0] :  53213/53213    T3[0] : 874098/874098   T4[0] :  59796/59796    T5[0] :   2519/2519     T6[0] :      0/571      T7[0] :      0/0        T8[0] :     11/758438   
    T1[+] : 179840/179840   T2[+] :  26178/26178    T3[+] : 428935/428935   T4[+] :  29430/29430    T5[+] :   1213/1213     T6[+] :      0/289      T7[+] :      0/0        T8[+] :      5/372245   
    T1[-] : 180335/180335   T2[-] :  26098/26098    T3[-] : 429214/429214   T4[-] :  29283/29283    T5[-] :   1267/1267     T6[-] :      0/276      T7[-] :      0/0        T8[-] :      5/372289   
    
    AVERAGE CURRENT
    BCM x1 : 10.3495uA  BCM x3 : 5.0521 uA  BCM x10: 10.3684uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    977.3 ppm     BCM u3 :      952 ppm     BCM u10:    956.5 ppm     
    BCM d1 :    995.5 ppm     BCM d3 :    1E+39 ppm     BCM d10:    949.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.007496       BCM u3 [0]:0.0075         BCM u10[0]:0.00752        
    BCM u1 [+]:0.003682       BCM u3 [+]:0.003685       BCM u10[+]:0.003694       
    BCM u1 [-]:0.003676       BCM u3 [-]:0.003678       BCM u10[-]:0.003687       
    
    BCM d1 [0]:0.007835       BCM d3 [0]:-1.672E-05     BCM d10[0]:0.007839       
    BCM d1 [+]:0.003849       BCM d3 [+]:-8.213E-06     BCM d10[+]:0.003851       
    BCM d1 [-]:0.003842       BCM d3 [-]:-8.2E-06       BCM d10[-]:0.003844       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4181 at Thu Mar 14 02:27:38 EST 2002
    Left Arm D1 momentum : 2.06
    Left Arm arm angle : 26.1668
    Tiefenbach Hall A energy : 5753.75
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.58984
    Left Arm Bottom VDC Current : 2.09961
    Left Arm Q1 power supply current : 1549.83
    Left Arm Q1 momentum : 2.06004
    Left Arm Q1 gauss meter : 0.1316
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 887.092
    Left Arm Q2 momentum : 2.06013
    Left Arm Q2 gauss meter : -0.4675
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 700.674
    Left Arm D1 momentum : 2.05999
    Left Arm D1 NMR : 0.762256
    Left Arm Q3 power supply current : 820.21
    Left Arm Q3 momentum : 2.06021
    Left Arm Q3 gauss meter : 0.4105
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 5.17876
    Current on Unser monitor : 10.1987
    Current on Upstream bcm : 10.3104
    Current on Downstream bcm : 0.0471145
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.75
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.616992
    HacL_HPE1313A:0_Ch58 : -0.155762
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.286133
    HacL_alignROLL : 0.0783517
    HacL_alignPITCH : -0.104637
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 160
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.744882
    Arc OTR y-position : 0.33626
    Arc OTR x-width : 4.40138
    Arc OTR y-width : 3.54669
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0