• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:44:53 on March 14, 2002

    Entry number 1658

    keyword=End_of_Run_4184
    ****************************
     Run Number: 4184
     End of Run Comment:
    Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Kinematics 15, 15 cm LH2 target, without rich, HV 1550V Ar/CH4,daq_mode=coincidence,leftarm_p=2.060,leftarm_theta=26.167,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=15cm LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=1900   ps2=150   ps3=7000   ps4=350   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 203632       [+]: 100253       [-]: 99637        
    TIME  [0]: 91.395 mins  [+]: 44.848 mins  [-]: 44.848 mins  
    LIVE  [0]:  99.85%      [+]:  99.71%      [-]:  99.98%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 2.7/5209.2 Hz   T2[0] : 2.7/402.4 Hz   T3[0] : 1.9/13541.5 Hz   T4[0] : 2.0/714.4 Hz   T5[0] :27.8/27.8 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 2.7/5213.8 Hz   T2[+] : 2.7/403.0 Hz   T3[+] : 1.9/13553.1 Hz   T4[+] : 2.0/715.7 Hz   T5[+] :27.9/27.9 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 2.7/5206.0 Hz   T2[-] : 2.7/401.8 Hz   T3[-] : 1.9/13532.4 Hz   T4[-] : 2.0/713.1 Hz   T5[-] :27.6/27.6 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  15034/28565441  T2[0] :  14710/2206505  T3[0] :  10608/74257325  T4[0] :  11192/3917324  T5[0] : 152303/152303   T6[0] :      0/0        T7[0] :      0/0        T8[0] :     85/5615288  
    T1[+] :   7383/14029576  T2[+] :   7228/1084321  T3[+] :   5209/36469428  T4[+] :   5502/1925806  T5[+] :  75183/75183    T6[+] :      0/0        T7[+] :      0/0        T8[+] :     42/2755434  
    T1[-] :   7372/14008694  T2[-] :   7207/1081168  T3[-] :   5201/36413612  T4[-] :   5482/1918947  T5[-] :  74349/74349    T6[-] :      0/0        T7[-] :      0/0        T8[-] :     42/2755436  
    
    AVERAGE CURRENT
    BCM x1 : 21.4073uA  BCM x3 : 10.4770uA  BCM x10: 21.1598uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :      653 ppm     BCM u3 :      632 ppm     BCM u10:    622.3 ppm     
    BCM d1 :    656.2 ppm     BCM d3 :    1E+39 ppm     BCM d10:    492.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1147         BCM u3 [0]:0.115          BCM u10[0]:0.115          
    BCM u1 [+]:0.05631        BCM u3 [+]:0.05648        BCM u10[+]:0.05647        
    BCM u1 [-]:0.05624        BCM u3 [-]:0.05641        BCM u10[-]:0.0564         
    
    BCM d1 [0]:0.1201         BCM d3 [0]:-0.0001238     BCM d10[0]:0.1171         
    BCM d1 [+]:0.05898        BCM d3 [+]:-6.08E-05      BCM d10[+]:0.05748        
    BCM d1 [-]:0.0589         BCM d3 [-]:-6.069E-05     BCM d10[-]:0.05742        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4184 at Thu Mar 14 04:44:46 EST 2002
    Left Arm D1 momentum : 2.06
    Left Arm arm angle : 26.1668
    Tiefenbach Hall A energy : 5753.52
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.05273
    Left Arm Bottom VDC Current : 3.07617
    Left Arm Q1 power supply current : 1549.87
    Left Arm Q1 momentum : 2.06009
    Left Arm Q1 gauss meter : 0.13163
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 886.998
    Left Arm Q2 momentum : 2.05991
    Left Arm Q2 gauss meter : -0.4675
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 700.666
    Left Arm D1 momentum : 2.06
    Left Arm D1 NMR : 0.762257
    Left Arm Q3 power supply current : 820.106
    Left Arm Q3 momentum : 2.06008
    Left Arm Q3 gauss meter : 0.4106
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0306568
    Current on Unser monitor : 7.46455
    Current on Upstream bcm : 0.0346806
    Current on Downstream bcm : 0.026633
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.52
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0328834
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.154297
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.283203
    HacL_alignROLL : 0.0811423
    HacL_alignPITCH : -0.106094
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 230
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.701829
    Arc OTR y-position : 0.309792
    Arc OTR x-width : 4.40831
    Arc OTR y-width : 3.55249
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0