• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:07:37 on March 14, 2002

    Entry number 1679

    keyword=End_of_Run_4194
    ****************************
     Run Number: 4194
     End of Run Comment:
    Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=production kin 15, with rich,,daq_mode=coincidence,leftarm_p=2.060,leftarm_theta=26.167,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=15cm LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=1900   ps2=150   ps3=7000   ps4=350   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 428666       [+]: 210153       [-]: 210542       
    TIME  [0]: 51.991 mins  [+]: 25.516 mins  [-]: 25.519 mins  
    LIVE  [0]:  96.92%      [+]:  96.84%      [-]:  96.94%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.7/16444.1 Hz   T2[0] : 8.5/1268.2 Hz   T3[0] : 6.1/42507.2 Hz   T4[0] : 6.4/2243.5 Hz   T5[0] :112.2/112.2 Hz   T6[0] : 0.0/426.8 Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 8.7/16450.4 Hz   T2[+] : 8.5/1269.5 Hz   T3[+] : 6.1/42521.4 Hz   T4[+] : 6.4/2244.1 Hz   T5[+] :112.1/112.1 Hz   T6[+] : 0.0/426.6 Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 8.6/16435.5 Hz   T2[-] : 8.4/1266.7 Hz   T3[-] : 6.1/42485.7 Hz   T4[-] : 6.4/2242.4 Hz   T5[-] :112.3/112.3 Hz   T6[-] : 0.0/426.7 Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  26998/51297036  T2[0] :  26373/3956071  T3[0] :  18942/132600445  T4[0] :  19995/6998576  T5[0] : 349920/349920   T6[0] :     20/1331301  T7[0] :      0/0        T8[0] :     48/3194349  
    T1[+] :  13255/25185028  T2[+] :  12956/1943537  T3[+] :   9299/65099034  T4[+] :   9816/3435701  T5[+] : 171645/171645   T6[+] :      9/653186   T7[+] :      0/0        T8[+] :     23/1567713  
    T1[-] :  13244/25165408  T2[-] :  12930/1939537  T3[-] :   9293/65052684  T4[-] :   9809/3433419  T5[-] : 171886/171886   T6[-] :      9/653277   T7[-] :      0/0        T8[-] :     23/1567914  
    
    AVERAGE CURRENT
    BCM x1 : 69.9910uA  BCM x3 : 34.2873uA  BCM x10: -49.7922uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :      404 ppm     BCM u3 :    396.2 ppm     BCM u10:    271.4 ppm     
    BCM d1 :    405.2 ppm     BCM d3 :    1E+39 ppm     BCM d10:    105.2 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.213          BCM u3 [0]:0.214          BCM u10[0]:-0.1459        
    BCM u1 [+]:0.1046         BCM u3 [+]:0.1051         BCM u10[+]:0.09684        
    BCM u1 [-]:0.1045         BCM u3 [-]:0.105          BCM u10[-]:0.0968         
    
    BCM d1 [0]:0.2237         BCM d3 [0]:-7.043E-05     BCM d10[0]:-0.1647        
    BCM d1 [+]:0.1098         BCM d3 [+]:-3.459E-05     BCM d10[+]:0.08476        
    BCM d1 [-]:0.1097         BCM d3 [-]:-3.453E-05     BCM d10[-]:0.08475        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4194 at Thu Mar 14 12:07:30 EST 2002
    Left Arm D1 momentum : 2.06
    Left Arm arm angle : 26.1668
    Tiefenbach Hall A energy : 5753.78
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.09961
    Left Arm Bottom VDC Current : -0.683594
    Left Arm Q1 power supply current : 1549.87
    Left Arm Q1 momentum : 2.06009
    Left Arm Q1 gauss meter : 0.13163
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 887.08
    Left Arm Q2 momentum : 2.0601
    Left Arm Q2 gauss meter : -0.4675
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 700.677
    Left Arm D1 momentum : 2.06001
    Left Arm D1 NMR : 0.762261
    Left Arm Q3 power supply current : 820.218
    Left Arm Q3 momentum : 2.06023
    Left Arm Q3 gauss meter : 0.4106
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 76.2442
    Current on Unser monitor : 83.8399
    Current on Upstream bcm : 76.114
    Current on Downstream bcm : 76.3743
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 76.4473
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.78
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.450755
    IPM1C12.XPOS : -0.000547856
    IPM1H04A.XPOS : 1.16823
    IPM1H04A.YPOS : 0.55176
    IPM1H04B.XPOS : 0.0523736
    IPM1H04B.YPOS : -0.0319555
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.154297
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : -0.280273
    HacL_alignROLL : 0.0838811
    HacL_alignPITCH : -0.105724
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 581
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.730174
    Arc OTR y-position : 0.30604
    Arc OTR x-width : 4.40401
    Arc OTR y-width : 3.54341
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0