• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:52:21 on March 14, 2002

    Entry number 1690

    keyword=End_of_Run_4197
    ****************************
     Run Number: 4197
     End of Run Comment:
    Run_type=optics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=kinematics 16, optics target,daq_mode=coincidence,leftarm_p=2.060,leftarm_theta=12.50,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=optics target,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=3   ps2=20   ps3=100   ps4=200   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 1001944      [+]: 492289       [-]: 491207       
    TIME  [0]: 26.154 mins  [+]: 12.838 mins  [-]: 12.835 mins  
    LIVE  [0]:  90.87%      [+]:  90.88%      [-]:  90.86%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :315.0/945.0 Hz   T2[0] : 6.8/135.0 Hz   T3[0] :364.2/36422.0 Hz   T4[0] : 7.7/1546.9 Hz   T5[0] : 8.9/8.9  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :315.3/945.9 Hz   T2[+] : 6.7/134.7 Hz   T3[+] :364.5/36451.8 Hz   T4[+] : 7.7/1547.2 Hz   T5[+] : 9.0/9.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :314.6/943.9 Hz   T2[-] : 6.8/135.4 Hz   T3[-] :364.0/36396.9 Hz   T4[-] : 7.7/1546.7 Hz   T5[-] : 8.9/8.9  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 494307/1482921  T2[0] :  10594/211898   T3[0] : 571543/57154372  T4[0] :  12137/2427470  T5[0] :  14008/14008    T6[0] :      0/0        T7[0] :      0/0        T8[0] :     24/1606890  
    T1[+] : 242868/728605   T2[+] :   5187/103757   T3[+] : 280776/28077677  T4[+] :   5958/1191770  T5[+] :   6920/6920     T6[+] :      0/0        T7[+] :      0/0        T8[+] :     12/788755   
    T1[-] : 242304/726913   T2[-] :   5215/104308   T3[-] : 280302/28030206  T4[-] :   5955/1191190  T5[-] :   6846/6846     T6[-] :      0/0        T7[-] :      0/0        T8[-] :     12/788610   
    
    AVERAGE CURRENT
    BCM x1 : 19.9215uA  BCM x3 : 9.7492 uA  BCM x10: 19.9537uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    586.1 ppm     BCM u3 :    568.3 ppm     BCM u10:    573.8 ppm     
    BCM d1 :    600.4 ppm     BCM d3 :    1E+39 ppm     BCM d10:      567 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03054        BCM u3 [0]:0.03063        BCM u10[0]:0.03069        
    BCM u1 [+]:0.015          BCM u3 [+]:0.01505        BCM u10[+]:0.01507        
    BCM u1 [-]:0.01498        BCM u3 [-]:0.01503        BCM u10[-]:0.01505        
    
    BCM d1 [0]:0.03198        BCM d3 [0]:-3.543E-05     BCM d10[0]:0.03193        
    BCM d1 [+]:0.01571        BCM d3 [+]:-1.74E-05      BCM d10[+]:0.01568        
    BCM d1 [-]:0.01569        BCM d3 [-]:-1.737E-05     BCM d10[-]:0.01566        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4197 at Thu Mar 14 17:52:16 EST 2002
    Left Arm D1 momentum : 2.06
    Left Arm arm angle : 12.5011
    Tiefenbach Hall A energy : 5753.74
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -4.3457
    Left Arm Bottom VDC Current : -1.51367
    Left Arm Q1 power supply current : 1549.87
    Left Arm Q1 momentum : 2.06009
    Left Arm Q1 gauss meter : 0.13165
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 887.008
    Left Arm Q2 momentum : 2.05994
    Left Arm Q2 gauss meter : -0.4675
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 700.682
    Left Arm D1 momentum : 2.06
    Left Arm D1 NMR : 0.762258
    Left Arm Q3 power supply current : 820.239
    Left Arm Q3 momentum : 2.06029
    Left Arm Q3 gauss meter : 0.4106
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 24.1221
    Current on Unser monitor : 31.4514
    Current on Upstream bcm : 24.0082
    Current on Downstream bcm : 24.236
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 24.3193
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.74
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.36219
    IPM1C12.XPOS : -0.0167971
    IPM1H04A.XPOS : 1.1725
    IPM1H04A.YPOS : 0.501639
    IPM1H04B.XPOS : 0.103752
    IPM1H04B.YPOS : -0.0394613
    Left Arm Arm Collimator : 0.617041
    HacL_HPE1313A:0_Ch58 : -0.219238
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : 0.0576172
    HacL_alignROLL : 0.395373
    HacL_alignPITCH : -0.0674918
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.617041
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 236
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.753115
    Arc OTR y-position : 0.285555
    Arc OTR x-width : 4.39983
    Arc OTR y-width : 3.5421
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0