• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:40:58 on March 14, 2002

    Entry number 1697

    keyword=End_of_Run_4199
    ****************************
     Run Number: 4199
     End of Run Comment:
    Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=kinematics 16, 15 cm LH2, 25 micro-A, prescale 1800/150/75000/3000/1,daq_mode=coincidence,leftarm_p=2.060,leftarm_theta=12.50,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=15cm LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=1800   ps2=150   ps3=75000   ps4=3000   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 174216       [+]: 85591        [-]: 85413        
    TIME  [0]: 16.783 mins  [+]: 8.236 mins  [-]: 8.237 mins  
    LIVE  [0]:  94.37%      [+]:  94.26%      [-]:  94.44%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.0/5451.5 Hz   T2[0] : 2.9/429.5 Hz   T3[0] : 2.9/218101.3 Hz   T4[0] : 3.0/9020.4 Hz   T5[0] :171.5/171.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 3.0/5453.5 Hz   T2[+] : 2.9/430.4 Hz   T3[+] : 2.9/218266.5 Hz   T4[+] : 3.0/9024.8 Hz   T5[+] :171.9/171.9 Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 3.0/5450.3 Hz   T2[-] : 2.9/428.9 Hz   T3[-] : 2.9/217972.1 Hz   T4[-] : 3.0/9017.4 Hz   T5[-] :171.2/171.2 Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   3049/5489641  T2[0] :   2883/432522   T3[0] :   2928/219628634  T4[0] :   3027/9083562  T5[0] : 172713/172713   T6[0] :      0/0        T7[0] :      0/0        T8[0] :     15/1031171  
    T1[+] :   1497/2694946  T2[+] :   1417/212698   T3[+] :   1438/107859485  T4[+] :   1486/4459733  T5[+] :  84962/84962    T6[+] :      0/0        T7[+] :      0/0        T8[+] :      7/506024   
    T1[-] :   1496/2693724  T2[-] :   1413/211983   T3[-] :   1436/107729756  T4[-] :   1485/4456712  T5[-] :  84608/84608    T6[-] :      0/0        T7[-] :      0/0        T8[-] :      7/506098   
    
    AVERAGE CURRENT
    BCM x1 : 22.0310uA  BCM x3 : 10.7741uA  BCM x10: 22.0698uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    682.9 ppm     BCM u3 :    664.5 ppm     BCM u10:    669.2 ppm     
    BCM d1 :    690.8 ppm     BCM d3 :    1E+39 ppm     BCM d10:    663.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02165        BCM u3 [0]:0.02172        BCM u10[0]:0.02176        
    BCM u1 [+]:0.01063        BCM u3 [+]:0.01067        BCM u10[+]:0.01069        
    BCM u1 [-]:0.01062        BCM u3 [-]:0.01065        BCM u10[-]:0.01067        
    
    BCM d1 [0]:0.02272        BCM d3 [0]:-2.274E-05     BCM d10[0]:0.02269        
    BCM d1 [+]:0.01116        BCM d3 [+]:-1.117E-05     BCM d10[+]:0.01114        
    BCM d1 [-]:0.01114        BCM d3 [-]:-1.115E-05     BCM d10[-]:0.01113        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4199 at Thu Mar 14 18:40:47 EST 2002
    Left Arm D1 momentum : 2.06
    Left Arm arm angle : 12.5011
    Tiefenbach Hall A energy : 5753.72
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -9.91211
    Left Arm Bottom VDC Current : -11.7188
    Left Arm Q1 power supply current : 1549.87
    Left Arm Q1 momentum : 2.06009
    Left Arm Q1 gauss meter :
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 886.932
    Left Arm Q2 momentum : 2.05976
    Left Arm Q2 gauss meter : -0.4674
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 700.671
    Left Arm D1 momentum : 2.06
    Left Arm D1 NMR : 0.762258
    Left Arm Q3 power supply current : 820.037
    Left Arm Q3 momentum : 2.05978
    Left Arm Q3 gauss meter : 0.4106
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 24.4108
    Current on Unser monitor : 32.3022
    Current on Upstream bcm : 24.2885
    Current on Downstream bcm : 24.5332
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 24.4316
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.72
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.357722
    IPM1C12.XPOS : 0.0200567
    IPM1H04A.XPOS : 1.19125
    IPM1H04A.YPOS : 0.476082
    IPM1H04B.XPOS : 0.106856
    IPM1H04B.YPOS : -0.0526633
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.218262
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.0566406
    HacL_alignROLL : 0.3946
    HacL_alignPITCH : -0.0693838
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 238
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.751001
    Arc OTR y-position : 0.284825
    Arc OTR x-width : 4.40575
    Arc OTR y-width : 3.5425
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0