Log entry time 20:21:21 on March 14, 2002
Entry number 1709
keyword=Start_Run_4205,Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=kinematics 16, 15 cm LH2, 75 micro-A, prescale 1800/150/75000/3000/1,daq_mode=coincidence,leftarm_p=2.060,leftarm_theta=12.50,photonarm_D=hrs,photonarm_angle=18.84,photonarm_p=-3.018,target_name=15cm LH2,target_type=15LH2
Beginning-of-run EPICS data for Run Number 4205 at Thu Mar 14 20:21:14 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the Right spectrometer based on T1 defined by S1*S2
; PS2 for the Right spectrometer based on T2 defined by S1*S0+S2*S0
; PS3 for the Left spectrometer based on T3 defined by S1*S2
; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
; PS5 for coincidence of T1 and T3.
; PS7 irrelevant
; PS8 for pulser
ps1=1800,ps2=150,ps3=75000,ps4=3000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 power supply current : 1549.83
Left Arm Q1 momentum : 2.06004
Left Arm Q1 gauss meter : 0.13162
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 887.038
Left Arm Q2 momentum : 2.06001
Left Arm Q2 gauss meter : -0.4674
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 700.68
Left Arm D1 momentum : 2.06
Left Arm D1 NMR : 0.762259
Left Arm Q3 power supply current : 820.099
Left Arm Q3 momentum : 2.05994
Left Arm Q3 gauss meter : 0.4106
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -22.4121
Left Arm Bottom VDC Current : -24.0723
Average current of the two cavities : 75.1402
Current on Unser monitor : 83.7173
Current on Upstream bcm : 74.7428
Current on Downstream bcm : 75.5377
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 75.1522
Tiefenbach Hall A energy : 5753.75
Tiefenbach Hall C energy : 1201.48
Delta(E)/E width (MV_AI_DXWID) : 0.458236
MBSY1c Hall A Beam energy : 5765.77
MBSY3c Hall C Beam energy : 1204.48
MBSY1c magnet current (amp) : 241.034
MBSY1c Bdl : 1.43885e+06
Arc1 dp/p : 4.73724e-05
Arc2 dp/p : -0.00122675
Left Arm Arm Collimator : 0.616943
HacL_HPE1313A:0_Ch58 : -0.217773
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.0571289
HacL_alignROLL : 0.3946
HacL_alignPITCH : -0.0693838
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -55.5
Left Arm Scattering Angle : 12.5011
IPM1C12.XPOS : -0.0184396
IPM1C12.YPOS : 0.0384172
IPM1H04A.XPOS : 1.17228
IPM1H04A.YPOS : 0.520688
IPM1H04B.XPOS : 0.0802717
IPM1H04B.YPOS : -0.0144453
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 96.1695
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 2234.6
Wien field : 64.112
Laser attenuation Hall A : 540
Laser power Hall A : 63
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -0.733876
Arc OTR y-position : 0.257509
Arc OTR x-width : 4.40691
Arc OTR y-width : 3.54332
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0