• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 16:41:32 on March 15, 2002

    Entry number 1793

    keyword=Start_Run_4234,Run_type=other,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=target boiling study, kinematics 17, 15cm dummy, 10.6 micro-A, FR on prescale 10/100/200/800/1, UNBUFF,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,target_name=dummy,target_type=15Empty
    Beginning-of-run EPICS data for Run Number 4234 at Fri Mar 15 16:41:27 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1*S0+S2*S0
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ; ps1=600,ps2=50,ps3=25000,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
    ps1=10,ps2=100,ps3=200,ps4=800,ps5=1,ps6=65535,ps7=65535,ps8=65535 
    Left Arm Q1 power supply current : 1309.67
    Left Arm Q1 momentum : 1.74081
    Left Arm Q1 gauss meter : 0.11141
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 749.567
    Left Arm Q2 momentum : 1.74075
    Left Arm Q2 gauss meter : -0.3952
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 586.104
    Left Arm D1 momentum : 1.741
    Left Arm D1 NMR : 0.64429
    Left Arm Q3 power supply current : 693.126
    Left Arm Q3 momentum : 1.741
    Left Arm Q3 gauss meter : 0.347
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : -2.05078
    Left Arm Bottom VDC Current : -3.80859
    Average current of the two cavities : 10.6483
    Current on Unser monitor : 19.0305
    Current on Upstream bcm : 10.6031
    Current on Downstream bcm : 10.6936
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 10.6378
    Tiefenbach Hall A energy : 5754.04
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.115083
    MBSY1c Hall A Beam energy : 5765.77
    MBSY3c Hall C Beam energy : 1204.48
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    Arc1 dp/p : 4.93075e-05
    Arc2 dp/p : -0.00112737
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.134277
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : -0.222168
    HacL_alignROLL : 0.135761
    HacL_alignPITCH : -0.123842
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 23
    Left Arm Angle Vernier : -28
    Left Arm Scattering Angle : 22.6596
    IPM1C12.XPOS : -0.207054
    IPM1C12.YPOS : 0.0681347
    IPM1H04A.XPOS : 1.15662
    IPM1H04A.YPOS : 0.52361
    IPM1H04B.XPOS : 0.209485
    IPM1H04B.YPOS : -0.165884
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 166
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.733611
    Arc OTR y-position : 0.306177
    Arc OTR x-width : 4.40422
    Arc OTR y-width : 3.55042
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0