• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:51:18 on March 15, 2002

    Entry number 1801

    keyword=End_of_Run_4237
    ****************************
     Run Number: 4237
     End of Run Comment:
    Run_type=other,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=target boiling study, kinematics 17, 4cm LH2 target, 29.7 micro-A, FR on prescale 10/100/200/800/1, UNBUFF,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,target_name=dummy,target_type=15Empty
     
    
    PRESCALE FACTORS:ps1=10   ps2=100   ps3=200   ps4=800   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 207982       [+]: 102106       [-]: 102004       
    TIME  [0]: 14.699 mins  [+]: 7.211 mins  [-]: 7.211 mins  
    LIVE  [0]:  95.60%      [+]:  95.60%      [-]:  95.65%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :115.2/1152.2 Hz   T2[0] : 1.6/158.3 Hz   T3[0] :119.9/23972.0 Hz   T4[0] : 1.3/1012.2 Hz   T5[0] : 8.7/8.7  Hz   T6[0] : 0.0/1287.4 Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :115.4/1154.2 Hz   T2[+] : 1.6/158.3 Hz   T3[+] :119.9/23989.6 Hz   T4[+] : 1.3/1013.5 Hz   T5[+] : 8.6/8.6  Hz   T6[+] : 0.0/1287.9 Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :115.0/1149.8 Hz   T2[-] : 1.6/158.4 Hz   T3[-] :119.8/23953.5 Hz   T4[-] : 1.3/1011.1 Hz   T5[-] : 8.9/8.9  Hz   T6[-] : 0.0/1285.4 Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 101616/1016161  T2[0] :   1395/139572   T3[0] : 105708/21141673  T4[0] :   1115/892718   T5[0] :   7696/7696     T6[0] :     17/1135362  T7[0] :      0/0        T8[0] :     13/903099   
    T1[+] :  49940/499406   T2[+] :    684/68491    T3[+] :  51897/10379511  T4[+] :    548/438498   T5[+] :   3728/3728     T6[+] :      8/557252   T7[+] :      0/0        T8[+] :      6/443052   
    T1[-] :  49750/497506   T2[-] :    685/68531    T3[-] :  51819/10363999  T4[-] :    546/437494   T5[-] :   3832/3832     T6[-] :      8/556140   T7[-] :      0/0        T8[-] :      6/443055   
    
    AVERAGE CURRENT
    BCM x1 : 26.8083uA  BCM x3 : 13.1250uA  BCM x10: 26.8521uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    886.9 ppm     BCM u3 :    862.5 ppm     BCM u10:    871.4 ppm     
    BCM d1 :    892.8 ppm     BCM d3 :    1E+39 ppm     BCM d10:    860.2 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02308        BCM u3 [0]:0.02317        BCM u10[0]:0.02321        
    BCM u1 [+]:0.01133        BCM u3 [+]:0.01138        BCM u10[+]:0.0114         
    BCM u1 [-]:0.01131        BCM u3 [-]:0.01136        BCM u10[-]:0.01138        
    
    BCM d1 [0]:0.0242         BCM d3 [0]:-1.991E-05     BCM d10[0]:0.02415        
    BCM d1 [+]:0.01188        BCM d3 [+]:-9.776E-06     BCM d10[+]:0.01186        
    BCM d1 [-]:0.01186        BCM d3 [-]:-9.759E-06     BCM d10[-]:0.01184        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4237 at Fri Mar 15 17:51:11 EST 2002
    Left Arm D1 momentum : 1.74099
    Left Arm arm angle : 22.6596
    Tiefenbach Hall A energy : 5753.73
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.61328
    Left Arm Bottom VDC Current : -2.7832
    Left Arm Q1 power supply current : 1309.67
    Left Arm Q1 momentum : 1.74081
    Left Arm Q1 gauss meter : 0.11141
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 749.82
    Left Arm Q2 momentum : 1.74134
    Left Arm Q2 gauss meter : -0.3952
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 586.1
    Left Arm D1 momentum : 1.74099
    Left Arm D1 NMR : 0.644285
    Left Arm Q3 power supply current : 693.086
    Left Arm Q3 momentum : 1.7409
    Left Arm Q3 gauss meter : 0.347
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 35.1721
    Current on Unser monitor : 43.4706
    Current on Upstream bcm : 34.8065
    Current on Downstream bcm : 35.5377
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 35.4733
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.73
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.134099
    IPM1C12.XPOS : -0.0140295
    IPM1H04A.XPOS : 1.17838
    IPM1H04A.YPOS : 0.491408
    IPM1H04B.XPOS : 0.214026
    IPM1H04B.YPOS : -0.151688
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.135742
    HacL_HPE1313A:0_Ch55 : 22.7539
    HacL_HPE1313A:0_Ch54 : -0.22168
    HacL_alignROLL : 0.135032
    HacL_alignPITCH : -0.122235
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 302
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.711938
    Arc OTR y-position : 0.256654
    Arc OTR x-width : 4.4104
    Arc OTR y-width : 3.54432
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0