• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:42:43 on March 15, 2002

    Entry number 1839

    keyword=End_of_Run_4256
    ****************************
     Run Number: 4256
     End of Run Comment:
    Run_type=other,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=target boiling study, kinematics 17, Carbon0optics target, 10.4 micro-A, FR on prescale 2/100/40/800/1, UNBUFF,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,target_name=dummy,target_type=15Empty
     
    
    PRESCALE FACTORS:ps1=2   ps2=100   ps3=40   ps4=800   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 201949       [+]: 99180        [-]: 98995        
    TIME  [0]: 17.376 mins  [+]: 8.524 mins  [-]: 8.523 mins  
    LIVE  [0]:  96.06%      [+]:  96.03%      [-]:  96.16%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.0/193.9 Hz   T2[0] : 0.6/56.2 Hz   T3[0] :100.5/4020.5 Hz   T4[0] : 0.2/193.7 Hz   T5[0] : 3.3/3.3  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :97.1/194.1 Hz   T2[+] : 0.6/56.1 Hz   T3[+] :100.6/4023.8 Hz   T4[+] : 0.2/193.9 Hz   T5[+] : 3.5/3.5  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :96.9/193.7 Hz   T2[-] : 0.6/56.3 Hz   T3[-] :100.4/4017.2 Hz   T4[-] : 0.2/193.7 Hz   T5[-] : 3.2/3.2  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 101104/202208   T2[0] :    586/58602    T3[0] : 104792/4191700  T4[0] :    252/201969   T5[0] :   3475/3475     T6[0] :      0/0        T7[0] :      0/0        T8[0] :     16/1067607  
    T1[+] :  49644/99289    T2[+] :    286/28673    T3[+] :  51451/2058055  T4[+] :    123/99161    T5[+] :   1768/1768     T6[+] :      0/0        T7[+] :      0/0        T8[+] :      7/523740   
    T1[-] :  49533/99067    T2[-] :    287/28786    T3[-] :  51354/2054193  T4[-] :    123/99049    T5[-] :   1648/1648     T6[-] :      0/0        T7[-] :      0/0        T8[-] :      7/523626   
    
    AVERAGE CURRENT
    BCM x1 : 8.6947 uA  BCM x3 : 4.2450 uA  BCM x10: 8.7104 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1043 ppm     BCM u3 :     1000 ppm     BCM u10:     1006 ppm     
    BCM d1 :     1048 ppm     BCM d3 :    1E+39 ppm     BCM d10:    997.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.008876       BCM u3 [0]:0.008875       BCM u10[0]:0.0089         
    BCM u1 [+]:0.004359       BCM u3 [+]:0.004358       BCM u10[+]:0.00437        
    BCM u1 [-]:0.004349       BCM u3 [-]:0.004348       BCM u10[-]:0.004361       
    
    BCM d1 [0]:0.009254       BCM d3 [0]:-2.354E-05     BCM d10[0]:0.009263       
    BCM d1 [+]:0.004544       BCM d3 [+]:-1.156E-05     BCM d10[+]:0.004548       
    BCM d1 [-]:0.004534       BCM d3 [-]:-1.153E-05     BCM d10[-]:0.004538       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4256 at Fri Mar 15 20:42:37 EST 2002
    Left Arm D1 momentum : 1.74101
    Left Arm arm angle : 22.6596
    Tiefenbach Hall A energy : 5753.74
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 1.61133
    Left Arm Bottom VDC Current : 3.85742
    Left Arm Q1 power supply current : 1309.81
    Left Arm Q1 momentum : 1.74099
    Left Arm Q1 gauss meter : 0.11143
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 749.789
    Left Arm Q2 momentum : 1.74127
    Left Arm Q2 gauss meter : -0.3952
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 586.111
    Left Arm D1 momentum : 1.74101
    Left Arm D1 NMR : 0.644291
    Left Arm Q3 power supply current : 693.093
    Left Arm Q3 momentum : 1.74092
    Left Arm Q3 gauss meter : 0.347
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0383026
    Current on Unser monitor : 7.04019
    Current on Upstream bcm : 0.0438228
    Current on Downstream bcm : 0.0327824
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.74
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.616895
    HacL_HPE1313A:0_Ch58 : -0.134766
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.221191
    HacL_alignROLL : 0.136429
    HacL_alignPITCH : -0.123183
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 166
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.737847
    Arc OTR y-position : 0.31354
    Arc OTR x-width : 4.40785
    Arc OTR y-width : 3.5485
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0