     Run Number: 4268
     End of Run Comment:
    Run_type=production,beam_energy=5.755,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=kinematics 1prime  -  with RICH,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,target_name=15cm LH,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=800   ps2=100   ps3=20000   ps4=800   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 645918       [+]: 317323       [-]: 316707       
    TIME  [0]: 92.669 mins  [+]: 45.465 mins  [-]: 45.466 mins  
    LIVE  [0]:  97.54%      [+]:  97.51%      [-]:  97.54%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 6.3/5048.5 Hz   T2[0] : 6.4/641.0 Hz   T3[0] : 6.0/119178.8 Hz   T4[0] : 7.5/6026.8 Hz   T5[0] :92.9/92.9 Hz   T6[0] : 0.0/497.3 Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 6.3/5050.4 Hz   T2[+] : 6.4/641.6 Hz   T3[+] : 6.0/119224.1 Hz   T4[+] : 7.5/6030.2 Hz   T5[+] :93.0/93.0 Hz   T6[+] : 0.0/497.5 Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 6.3/5048.9 Hz   T2[-] : 6.4/640.8 Hz   T3[-] : 6.0/119175.1 Hz   T4[-] : 7.5/6025.3 Hz   T5[-] :92.8/92.8 Hz   T6[-] : 0.0/497.3 Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  35088/28070539  T2[0] :  35641/3564101  T3[0] :  33132/662650994  T4[0] :  41887/33509661  T5[0] : 516340/516340   T6[0] :     42/2764900  T7[0] :      0/0        T8[0] :     86/5693587  
    T1[+] :  17221/13776977  T2[+] :  17502/1750260  T3[+] :  16261/325232638  T4[+] :  20562/16449739  T5[+] : 253821/253821   T6[+] :     20/1357245  T7[+] :      0/0        T8[+] :     42/2793379  
    T1[-] :  17216/13773301  T2[-] :  17479/1747955  T3[-] :  16255/325106699  T4[-] :  20546/16436924  T5[-] : 253123/253123   T6[-] :     20/1356659  T7[-] :      0/0        T8[-] :     42/2793447  
    
    AVERAGE CURRENT
    BCM x1 : 54.8629uA  BCM x3 : 26.8884uA  BCM x10: -9.4516uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    216.6 ppm     BCM u3 :    208.8 ppm     BCM u10:    166.1 ppm     
    BCM d1 :    216.6 ppm     BCM d3 :    1E+39 ppm     BCM d10:    76.16 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.2978         BCM u3 [0]:0.2991         BCM u10[0]:-0.0507        
    BCM u1 [+]:0.1461         BCM u3 [+]:0.1468         BCM u10[+]:0.1435         
    BCM u1 [-]:0.1461         BCM u3 [-]:0.1467         BCM u10[-]:0.1435         
    
    BCM d1 [0]:0.3123         BCM d3 [0]:-0.0001255     BCM d10[0]:-0.05441       
    BCM d1 [+]:0.1533         BCM d3 [+]:-6.164E-05     BCM d10[+]:0.1389         
    BCM d1 [-]:0.1532         BCM d3 [-]:-6.153E-05     BCM d10[-]:0.1389         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4268 at Sat Mar 16 22:41:51 EST 2002
    Left Arm D1 momentum : 1.74101
    Left Arm arm angle : 22.6596
    Tiefenbach Hall A energy : 5753.78
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.97852
    Left Arm Bottom VDC Current : -7.08008
    Left Arm Q1 power supply current : 1309.7
    Left Arm Q1 momentum : 1.74085
    Left Arm Q1 gauss meter : 0.11144
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 749.532
    Left Arm Q2 momentum : 1.74067
    Left Arm Q2 gauss meter : -0.3952
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 586.109
    Left Arm D1 momentum : 1.74101
    Left Arm D1 NMR : 0.644291
    Left Arm Q3 power supply current : 693.092
    Left Arm Q3 momentum : 1.74092
    Left Arm Q3 gauss meter : 0.347
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 60.7125
    Current on Unser monitor : 68.9665
    Current on Upstream bcm : 60.262
    Current on Downstream bcm : 61.163
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 61.2381
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5753.78
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.071232
    IPM1C12.XPOS : 0.0097746
    IPM1H04A.XPOS : 1.1035
    IPM1H04A.YPOS : 0.585624
    IPM1H04B.XPOS : 0.0215027
    IPM1H04B.YPOS : 0.0147894
    Left Arm Arm Collimator : 0.616943
    HacL_HPE1313A:0_Ch58 : -0.133789
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : -0.219238
    HacL_alignROLL : 0.138708
    HacL_alignPITCH : -0.125003
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.616943
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 500
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.750592
    Arc OTR y-position : 0.342799
    Arc OTR x-width : 4.39734
    Arc OTR y-width : 3.54603
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0