• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:03:51 on April 30, 2002

    Entry number 2214

    keyword=Start_Run_1080,Run_type=cosmics,beam_energy=5.755,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=cosmics,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=,rightarm_theta=,target_name=,target_type=Empty
    Beginning-of-run EPICS data for Run Number 1080 at Tue Apr 30 20:03:40 EDT 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1*S0+S2*S0
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ps1=1,ps2=1000,ps3=1,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
     
    Left Arm Q1 power supply current : 376.18
    Left Arm Q1 momentum : 0.500019
    Left Arm Q1 gauss meter : -0.03168
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 215.511
    Left Arm Q2 momentum : 0.500489
    Left Arm Q2 gauss meter : 0.11282
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 167.783
    Left Arm D1 momentum : 0.500001
    Left Arm D1 NMR : 0.18524
    Left Arm Q3 power supply current : 199.127
    Left Arm Q3 momentum : 0.50017
    Left Arm Q3 gauss meter : -0.09798
    Left Arm Q3 power supply polarity : 1
    Right Arm Q1 power supply current : 375.9
    Right Arm Q1 momentum : 0.49991
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 215.048
    Right Arm Q2 momentum : 0.499684
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 172.403
    Right Arm D1 momentum : 0.500002
    Right Arm D1 NMR : 0.185545
    Right Arm Q3 power supply current : 198.987
    Right Arm Q3 momentum : 0.500081
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -2.88086
    Left Arm Bottom VDC Current : 3.27148
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Average current of the two cavities : 0.0304514
    Current on Unser monitor : 5.08292
    Current on Upstream bcm : 0.0345293
    Current on Downstream bcm : 0.0263736
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 1162.25
    Tiefenbach Hall C energy : 2343.31
    Delta(E)/E width (MV_AI_DXWID) : 2.81158
    MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: opscagw1.acc.jlab.org Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 1163.18
    MBSY3c Hall C Beam energy : 2349.45
    MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: opscagw1.acc.jlab.org Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 48.1892
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: opscagw1.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 290272
    Arc1 dp/p : 0.000101963
    Arc2 dp/p : -0.00153119
    Left Arm Arm Collimator : 0.363721
    HacL_HPE1313A:0_Ch58 : -0.13623
    HacL_HPE1313A:0_Ch55 : 22.5098
    HacL_HPE1313A:0_Ch54 : -0.149902
    HacL_alignROLL : 0.200017
    HacL_alignPITCH : -0.121864
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 22.5
    Left Arm Angle Vernier : -27
    Left Arm Scattering Angle : 22.1654
    Right Arm Arm Collimator : 0.360645
    HacR_HPE1313A:0_Ch58 : -0.539062
    HacR_HPE1313A:0_Ch55 : 21.3867
    HacR_HPE1313A:0_Ch54 : -0.853027
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 22
    Right Arm Angle Vernier : -5
    Right Arm Scattering Angle : 22.1682
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -70.2265
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -1636.3
    Wien field : 46.79
    Laser attenuation Hall A : 120
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.325352
    Target OTR y-position : 1.94992
    Target OTR x-width : 3.10409
    Target OTR y-width : 3.25373
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 2.17121
    Arc OTR y-position : -1.54004
    Arc OTR x-width : 1.8389
    Arc OTR y-width : 4.89276
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0