NEXT
User name a-onl
Log entry time 16:17:05 on May 1, 2002
Entry number 2237
keyword=End_of_Run_1089
****************************
Run Number: 1089
End of Run Comment:
Run_type=cosmics,beam_energy=5.755,beam_raster=off,comment_text=,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=,rightarm_theta=,target_name=,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=1000 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 5903 [+]: 2978 [-]: 2824
TIME [0]: 3.049 mins [+]: 1.496 mins [-]: 1.496 mins
LIVE [0]: 83.89% [+]: 84.12% [-]: 83.77%
TRIGGER RATES: PRES/REAL
T1[0] :10.1/10.1 Hz T2[0] : 1.3/1326.5 Hz T3[0] :11.1/11.1 Hz T4[0] :12.9/12.9 Hz T5[0] : 3.1/3.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :10.7/10.7 Hz T2[+] : 1.3/1329.1 Hz T3[+] :11.0/11.0 Hz T4[+] :13.3/13.3 Hz T5[+] : 3.1/3.1 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 9.6/9.6 Hz T2[-] : 1.3/1323.0 Hz T3[-] :11.2/11.2 Hz T4[-] :12.5/12.5 Hz T5[-] : 3.0/3.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 1848/1848 T2[0] : 242/242704 T3[0] : 2030/2030 T4[0] : 2356/2356 T5[0] : 559/559 T8[0] : 2/187357
T1[+] : 961/961 T2[+] : 119/119293 T3[+] : 990/990 T4[+] : 1190/1190 T5[+] : 279/279 T8[+] : 1/91910
T1[-] : 862/862 T2[-] : 118/118754 T3[-] : 1001/1001 T4[-] : 1121/1121 T5[-] : 268/268 T8[-] : 1/91913
AVERAGE CURRENT
BCM x1 : 0.0100 uA BCM x3 : 0.0012 uA BCM x10: 0.0127 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 6420 ppm BCM u3 : 1E+39 ppm BCM u10: 347.4 ppm
BCM d1 : 1E+39 ppm BCM d3 : 2333 ppm BCM d10: 6921 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:8.686E-06 BCM u3 [0]:-2.044E-07 BCM u10[0]:3.444E-06
BCM u1 [+]:4.242E-06 BCM u3 [+]:-1.042E-07 BCM u10[+]:1.687E-06
BCM u1 [-]:4.188E-06 BCM u3 [-]:-1.022E-07 BCM u10[-]:1.686E-06
BCM d1 [0]:-5.039E-06 BCM d3 [0]:6.364E-07 BCM d10[0]:1.193E-06
BCM d1 [+]:-2.443E-06 BCM d3 [+]:3.144E-07 BCM d10[+]:5.921E-07
BCM d1 [-]:-2.538E-06 BCM d3 [-]:3.129E-07 BCM d10[-]:5.84E-07
****************************
End-of-run EPICS data for Run Number 1089 at Wed May 1 16:16:56 EDT 2002
Left Arm D1 momentum : 0.500004
Left Arm arm angle : 22.1654
Right Arm D1 momentum : 0.5
Right Arm arm angle : 22.1682
Tiefenbach Hall A energy : 2263.56
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -1.26953
Left Arm Bottom VDC Current : 2.05078
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 376.215
Left Arm Q1 momentum : 0.500065
Left Arm Q1 gauss meter : -0.0317
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 215.493
Left Arm Q2 momentum : 0.500449
Left Arm Q2 gauss meter : 0.11281
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 167.779
Left Arm D1 momentum : 0.500004
Left Arm D1 NMR : 0.185242
Left Arm Q3 power supply current : 198.985
Left Arm Q3 momentum : 0.499814
Left Arm Q3 gauss meter : -0.09789
Left Arm Q3 power supply polarity : 1
Right Arm Q1 power supply current : 375.9
Right Arm Q1 momentum : 0.49991
Right Arm Q1 gauss meter : -0.009412
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 215.124
Right Arm Q2 momentum : 0.499862
Right Arm Q2 gauss meter : 0.11214
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 172.396
Right Arm D1 momentum : 0.499999
Right Arm D1 NMR : 0.185544
Right Arm Q3 power supply current : 199.017
Right Arm Q3 momentum : 0.500157
Right Arm Q3 gauss meter : 0.08856
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.0335745
Current on Unser monitor : 3.99207
Current on Upstream bcm : 0.0398214
Current on Downstream bcm : 0.0273276
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 2266.3
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 565557
MBSY3c Hall C Beam energy : 2349.45
Tiefenbach Hall A energy : 2263.56
Tiefenbach Hall C energy : 2343.31
Delta(E)/E width (MV_AI_DXWID) : 5.88338
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.36377
Left LVDT HPM : 1614
Left LVDT VPM : 490
HacL_HPE1313A:0_Ch58 : -0.137695
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.152344
HacL_alignROLL : 0.198544
HacL_alignPITCH : -0.119979
HacL_alignHPT : -0
Right Arm Collimator : 0.360547
Right LVDT HPM : 1052
Right LVDT VPM : 166
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 21.5332
HacR_HPE1313A:0_Ch54 : -0.853027
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 70
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 0.375874
Target OTR y-position : 1.93291
Target OTR x-width : 3.12445
Target OTR y-width : 3.28658
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 2.31218
Arc OTR y-position : -2.4962
Arc OTR x-width : 2.01995
Arc OTR y-width : 4.62439
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0