NEXT
User name a-onl
Log entry time 23:39:44 on May 1, 2002
Entry number 2273
keyword=End_of_Run_1105
****************************
Run Number: 1105
End of Run Comment:
Run_type=other,beam_energy=2.26,beam_raster=off,comment_text=5mA beam, empty target, beam position (0,0) with epics,daq_mode=both HRS daq,leftarm_p=1.6,leftarm_theta=22.168,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=1.6,rightarm_theta=21.165,target_name=cryo,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=100 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 14799 [+]: 7267 [-]: 7283
TIME [0]: 5.208 mins [+]: 2.556 mins [-]: 2.556 mins
LIVE [0]: 85.81% [+]: 85.22% [-]: 86.49%
TRIGGER RATES: PRES/REAL
T1[0] : 9.9/9.9 Hz T2[0] :16.3/1629.7 Hz T3[0] :11.3/11.3 Hz T4[0] :14.7/14.7 Hz T5[0] : 3.0/3.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 9.8/9.8 Hz T2[+] :16.3/1628.8 Hz T3[+] :11.4/11.4 Hz T4[+] :14.9/14.9 Hz T5[+] : 3.1/3.1 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 9.9/9.9 Hz T2[-] :16.3/1629.9 Hz T3[-] :11.2/11.2 Hz T4[-] :14.4/14.4 Hz T5[-] : 3.0/3.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 3086/3086 T2[0] : 5092/509234 T3[0] : 3532/3532 T4[0] : 4579/4579 T5[0] : 953/953 T8[0] : 4/319970
T1[+] : 1510/1510 T2[+] : 2497/249797 T3[+] : 1754/1754 T4[+] : 2289/2289 T5[+] : 475/475 T8[+] : 2/157043
T1[-] : 1523/1523 T2[-] : 2499/249969 T3[-] : 1720/1720 T4[-] : 2212/2212 T5[-] : 465/465 T8[-] : 2/157043
AVERAGE CURRENT
BCM x1 : 4.2703 uA BCM x3 : 4.2771 uA BCM x10: 4.2877 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 91.18 ppm BCM u3 : 76.87 ppm BCM u10: 64.42 ppm
BCM d1 : 125.7 ppm BCM d3 : 77.78 ppm BCM d10: 64.35 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001316 BCM u3 [0]:0.001308 BCM u10[0]:0.001316
BCM u1 [+]:0.0006458 BCM u3 [+]:0.0006421 BCM u10[+]:0.0006459
BCM u1 [-]:0.0006456 BCM u3 [-]:0.000642 BCM u10[-]:0.0006458
BCM d1 [0]:0.001353 BCM d3 [0]:0.001365 BCM d10[0]:0.001364
BCM d1 [+]:0.000664 BCM d3 [+]:0.0006699 BCM d10[+]:0.0006694
BCM d1 [-]:0.0006639 BCM d3 [-]:0.0006698 BCM d10[-]:0.0006693
****************************
End-of-run EPICS data for Run Number 1105 at Wed May 1 23:39:35 EDT 2002
Left Arm D1 momentum : 1.60001
Left Arm arm angle : 22.1654
Right Arm D1 momentum : 1.59999
Right Arm arm angle : 22.1682
Tiefenbach Hall A energy : 2259.97
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -2.68555
Left Arm Bottom VDC Current : -2.34375
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1203.65
Left Arm Q1 momentum : 1.59989
Left Arm Q1 gauss meter : -0.10171
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 688.985
Left Arm Q2 momentum : 1.60006
Left Arm Q2 gauss meter : 0.3636
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 537.373
Left Arm D1 momentum : 1.60001
Left Arm D1 NMR : 0.592145
Left Arm Q3 power supply current : 636.919
Left Arm Q3 momentum : 1.59982
Left Arm Q3 gauss meter : -0.3187
Left Arm Q3 power supply polarity : 1
Right Arm Q1 power supply current : 1203.12
Right Arm Q1 momentum : 1.60004
Right Arm Q1 gauss meter : -0.0299
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 688.73
Right Arm Q2 momentum : 1.60033
Right Arm Q2 gauss meter : 0.362
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 550.672
Right Arm D1 momentum : 1.6
Right Arm D1 NMR : 0.59374
Right Arm Q3 power supply current : 636.538
Right Arm Q3 momentum : 1.59971
Right Arm Q3 gauss meter : 0.2857
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 2.71954
Current on Unser monitor : 10.0613
Current on Upstream bcm : 0.0368085
Current on Downstream bcm : 0.0284592
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.95
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 5.88338
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : -0.0307234
IPM1H04B.YPOS : -0.0321238
Left Arm Collimator : 0.61543
Left LVDT HPM : 1559
Left LVDT VPM : 542
HacL_HPE1313A:0_Ch58 : -0.137695
HacL_HPE1313A:0_Ch55 : 22.5586
HacL_HPE1313A:0_Ch54 : -0.152832
HacL_alignROLL : 0.197883
HacL_alignPITCH : -0.120192
HacL_alignHPT : -0
Right Arm Collimator : 0.612012
Right LVDT HPM : 1051
Right LVDT VPM : 251
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 21.2891
HacR_HPE1313A:0_Ch54 : -0.85498
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 60
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 0.263867
Target OTR y-position : 1.98503
Target OTR x-width : 3.12537
Target OTR y-width : 3.41398
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -1.7134
Arc OTR y-position : 0.169837
Arc OTR x-width : 4.47711
Arc OTR y-width : 3.75254
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0