keyword=Trigger/event size test runs.
Runs 1110-1113 had modified trigger conditions (and FPP turned on/off to check on the event size). Conclusions are that the looser trigger (where S1 requires any PMT, rather than one on each end) does not significantly increase the T1/T3 rates, and will allow us to measure the hodoscope efficiency. We will run with or-or. The event size is large (>2kB/event), but is not affected by the FPP chambers, so we will leave them turned on.
1110: Normal trigger (and-or for S12L logic and S12R logic). FPP turned ON
1111: Modified trigger (or-or). FPP turned ON
1112: Modified trigger (or-or). FPP turned OFF
1113: Normal trigger (and-or). FPP turned OFF.