NEXT
User name a-onl
Log entry time 03:38:42 on May 4, 2002
Entry number 2545
keyword=End_of_Run_1218
****************************
Run Number: 1218
End of Run Comment:
Run_type=elastic,beam_energy=2.260,beam_raster=on,comment_text=Target Luminosity Scan,6msr Coll,4 cm LH2, I=20uA,daq_mode=both HRS daq,leftarm_p=1.920,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=1.920,rightarm_theta=22.166,target_name=,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=16 ps2=800 ps3=16 ps4=50 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 403031 [+]: 198096 [-]: 197706
TIME [0]: 5.208 mins [+]: 2.556 mins [-]: 2.557 mins
LIVE [0]: 83.74% [+]: 83.82% [-]: 83.70%
TRIGGER RATES: PRES/REAL
T1[0] :754.8/12076.9 Hz T2[0] : 9.9/7919.5 Hz T3[0] :753.0/12048.0 Hz T4[0] : 2.5/127.5 Hz T5[0] :20.0/20.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :754.8/12076.3 Hz T2[+] : 9.9/7918.6 Hz T3[+] :753.3/12053.0 Hz T4[+] : 2.5/127.1 Hz T5[+] :20.5/20.5 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :754.8/12076.2 Hz T2[-] : 9.9/7920.9 Hz T3[-] :752.6/12042.0 Hz T4[-] : 2.6/128.0 Hz T5[-] :19.5/19.5 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 235855/3773692 T2[0] : 3093/2474642 T3[0] : 235291/3764658 T4[0] : 796/39828 T5[0] : 6237/6237 T8[0] : 4/319972
T1[+] : 115758/1852139 T2[+] : 1518/1214462 T3[+] : 115535/1848561 T4[+] : 389/19495 T5[+] : 3137/3137 T8[+] : 2/157050
T1[-] : 115812/1852995 T2[-] : 1519/1215394 T3[-] : 115484/1847746 T4[-] : 392/19646 T5[-] : 2993/2993 T8[-] : 2/157124
AVERAGE CURRENT
BCM x1 : 20.3619uA BCM x3 : 20.4158uA BCM x10: 20.4199uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 406.8 ppm BCM u3 : 397.4 ppm BCM u10: 395 ppm
BCM d1 : 411.1 ppm BCM d3 : 392.3 ppm BCM d10: 393.7 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.006231 BCM u3 [0]:0.006252 BCM u10[0]:0.006267
BCM u1 [+]:0.00306 BCM u3 [+]:0.00307 BCM u10[+]:0.003077
BCM u1 [-]:0.003059 BCM u3 [-]:0.003069 BCM u10[-]:0.003076
BCM d1 [0]:0.006494 BCM d3 [0]:0.006507 BCM d10[0]:0.006495
BCM d1 [+]:0.003189 BCM d3 [+]:0.003195 BCM d10[+]:0.003189
BCM d1 [-]:0.003188 BCM d3 [-]:0.003194 BCM d10[-]:0.003188
****************************
End-of-run EPICS data for Run Number 1218 at Sat May 4 03:38:32 EDT 2002
Left Arm D1 momentum : 1.92001
Left Arm arm angle : 22.1654
Right Arm D1 momentum : 1.92
Right Arm arm angle : 22.1682
Tiefenbach Hall A energy : 2259.95
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -3.17383
Left Arm Bottom VDC Current : -1.5625
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1444.52
Left Arm Q1 momentum : 1.92006
Left Arm Q1 gauss meter : -0.12209
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 826.851
Left Arm Q2 momentum : 1.92023
Left Arm Q2 gauss meter : 0.4362
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 649.949
Left Arm D1 momentum : 1.92001
Left Arm D1 NMR : 0.710486
Left Arm Q3 power supply current : 764.272
Left Arm Q3 momentum : 1.91971
Left Arm Q3 gauss meter : -0.3824
Left Arm Q3 power supply polarity : 1
Right Arm Q1 power supply current : 1443.71
Right Arm Q1 momentum : 1.92
Right Arm Q1 gauss meter : -0.03587
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 826.316
Right Arm Q2 momentum : 1.92003
Right Arm Q2 gauss meter : 0.4344
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 664.954
Right Arm D1 momentum : 1.92
Right Arm D1 NMR : 0.712488
Right Arm Q3 power supply current : 763.898
Right Arm Q3 momentum : 1.91978
Right Arm Q3 gauss meter : 0.3429
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 21.0735
Current on Unser monitor : 25.4924
Current on Upstream bcm : 21.0506
Current on Downstream bcm : 21.0964
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 21.1788
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.95
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 16.8501
IPM1C12.XPOS : 0.0194013
IPM1H04A.XPOS : 0.065364
IPM1H04A.YPOS : 0.201852
IPM1H04B.XPOS : 0.0235285
IPM1H04B.YPOS : 0.0108808
Left Arm Collimator : 0.615527
Left LVDT HPM : -487
Left LVDT VPM : 543
HacL_HPE1313A:0_Ch58 : -0.13623
HacL_HPE1313A:0_Ch55 : 22.5586
HacL_HPE1313A:0_Ch54 : -0.153809
HacL_alignROLL : 0.196926
HacL_alignPITCH : -0.121427
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : 1000
Right LVDT VPM : 243
HacR_HPE1313A:0_Ch58 : -0.539551
HacR_HPE1313A:0_Ch55 : 21.3379
HacR_HPE1313A:0_Ch54 : -0.853516
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 155
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.72991
Target OTR y-position : 0.140812
Target OTR x-width : 0.598841
Target OTR y-width : 0.361116
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 1.08732
Arc OTR y-position : -3.33275
Arc OTR x-width : 2.0682
Arc OTR y-width : 1.91569
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0