• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:51:27 on May 4, 2002

    Entry number 2564

    keyword=End_of_Run_1227
    ****************************
     Run Number: 1227
     End of Run Comment:
    Run_type=elastic,beam_energy=2.260,beam_raster=on,comment_text=Delta Scan -2% ,6msr Coll,Thin Carbon Target, I=10uA,daq_mode=both HRS daq,leftarm_p=-1.882,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=-1.882,rightarm_theta=22.166,target_name=,target_type=Carbon (thin)
     
    
    PRESCALE FACTORS:ps1=2   ps2=800   ps3=2   ps4=50   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 302762       [+]: 148579       [-]: 148617       
    TIME  [0]: 9.934 mins  [+]: 4.876 mins  [-]: 4.876 mins  
    LIVE  [0]:  87.57%      [+]:  87.56%      [-]:  87.61%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :284.4/568.8 Hz   T2[0] : 2.8/2220.3 Hz   T3[0] :289.1/578.2 Hz   T4[0] : 0.7/33.1 Hz   T5[0] : 3.1/3.1  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :284.2/568.4 Hz   T2[+] : 2.8/2222.9 Hz   T3[+] :289.3/578.5 Hz   T4[+] : 0.7/32.9 Hz   T5[+] : 3.2/3.2  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :284.4/568.9 Hz   T2[-] : 2.8/2217.8 Hz   T3[-] :288.8/577.6 Hz   T4[-] : 0.7/33.4 Hz   T5[-] : 3.1/3.1  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 169511/339022   T2[0] :   1654/1323321  T3[0] : 172318/344636   T4[0] :    395/19752    T5[0] :   1862/1862     T8[0] :      9/610322   
    T1[+] :  83141/166282   T2[+] :    812/650273   T3[+] :  84619/169239   T4[+] :    192/9634     T5[+] :    922/922      T8[+] :      4/299558   
    T1[-] :  83217/166434   T2[-] :    811/648861   T3[-] :  84498/168996   T4[-] :    195/9763     T5[-] :    908/908      T8[-] :      4/299587   
    
    AVERAGE CURRENT
    BCM x1 : 5.5079 uA  BCM x3 : 5.5205 uA  BCM x10: 5.5321 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    169.7 ppm     BCM u3 :      131 ppm     BCM u10:      118 ppm     
    BCM d1 :    193.1 ppm     BCM d3 :    121.1 ppm     BCM d10:    117.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.003231       BCM u3 [0]:0.003221       BCM u10[0]:0.003238       
    BCM u1 [+]:0.001586       BCM u3 [+]:0.001581       BCM u10[+]:0.00159        
    BCM u1 [-]:0.001585       BCM u3 [-]:0.001581       BCM u10[-]:0.001589       
    
    BCM d1 [0]:0.003334       BCM d3 [0]:0.003359       BCM d10[0]:0.003356       
    BCM d1 [+]:0.001637       BCM d3 [+]:0.001649       BCM d10[+]:0.001647       
    BCM d1 [-]:0.001636       BCM d3 [-]:0.001649       BCM d10[-]:0.001647       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1227 at Sat May 4 05:51:18 EDT 2002
    Left Arm D1 momentum : 1.88199
    Left Arm arm angle : 22.1654
    Right Arm D1 momentum : 1.882
    Right Arm arm angle : 22.1682
    Tiefenbach Hall A energy : 2259.94
    Left Arm arm mispointing (HPT) : -0
    Right Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -0.244141
    Left Arm Bottom VDC Current : -2.24609
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left Arm Q1 power supply current : 1415.82
    Left Arm Q1 momentum : 1.88191
    Left Arm Q1 gauss meter : -0.11967
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 810.367
    Left Arm Q2 momentum : 1.88195
    Left Arm Q2 gauss meter : 0.4276
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 636.203
    Left Arm D1 momentum : 1.882
    Left Arm D1 NMR : 0.696432
    Left Arm Q3 power supply current : 749.182
    Left Arm Q3 momentum : 1.88181
    Left Arm Q3 gauss meter : -0.3749
    Left Arm Q3 power supply polarity : 1
    Right Arm Q1 power supply current : 1415.12
    Right Arm Q1 momentum : 1.88197
    Right Arm Q1 gauss meter : -0.03517
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 810.018
    Right Arm Q2 momentum : 1.88216
    Right Arm Q2 gauss meter : 0.4257
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 650.836
    Right Arm D1 momentum : 1.88199
    Right Arm D1 NMR : 0.698386
    Right Arm Q3 power supply current : 748.702
    Right Arm Q3 momentum : 1.88159
    Right Arm Q3 gauss meter : 0.3361
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 9.431
    Current on Unser monitor : 14.1915
    Current on Upstream bcm : 9.43063
    Current on Downstream bcm : 9.43138
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 9.49406
    MBSY1c Hall A Beam energy : 2262.69
    MBSY1c magnet current (amp) : 94.162
    MBSY1c Bdl : 564657
    MBSY3c Hall C Beam energy : 5582.95
    Tiefenbach Hall A energy : 2259.94
    Tiefenbach Hall C energy : 5564.65
    Delta(E)/E width (MV_AI_DXWID) : 16.8501
    IPM1C12.XPOS : -0.00379574
    IPM1H04A.XPOS : 0.0921878
    IPM1H04A.YPOS : 0.227122
    IPM1H04B.XPOS : 0.0460558
    IPM1H04B.YPOS : -0.00407847
    Left Arm Collimator : 0.615527
    Left LVDT HPM : -537
    Left LVDT VPM : 612
    HacL_HPE1313A:0_Ch58 : -0.136719
    HacL_HPE1313A:0_Ch55 : 22.5586
    HacL_HPE1313A:0_Ch54 : -0.154785
    HacL_alignROLL : 0.196631
    HacL_alignPITCH : -0.121576
    HacL_alignHPT : -0
    Right Arm Collimator : 0.612061
    Right LVDT HPM : 956
    Right LVDT VPM : 313
    HacR_HPE1313A:0_Ch58 : -0.539551
    HacR_HPE1313A:0_Ch55 : 21.3379
    HacR_HPE1313A:0_Ch54 : -0.854492
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Wien angle : -70.2265
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -1636.3
    Wien field : 46.79
    Laser attenuation Hall A : 102
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 2.75055
    Target OTR y-position : 0.164338
    Target OTR x-width : 0.535733
    Target OTR y-width : 0.332754
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : 1.11233
    Arc OTR y-position : -3.44535
    Arc OTR x-width : 2.11954
    Arc OTR y-width : 1.84634
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0