NEXT
User name a-onl
Log entry time 05:42:03 on May 5, 2002
Entry number 2665
keyword=End_of_Run_1266
****************************
Run Number: 1266
End of Run Comment:
Run_type=production,beam_energy=2.260,beam_raster=on,comment_text=30 uA collimators in,daq_mode=Unbuff,leftarm_p=+2.149,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=60.075,target_name=,target_type=4cm Dummy
PRESCALE FACTORS:ps1=20 ps2=120 ps3=1 ps4=4 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 1002183 [+]: 491915 [-]: 492122
TIME [0]: 27.995 mins [+]: 13.745 mins [-]: 13.744 mins
LIVE [0]: 89.10% [+]: 89.11% [-]: 89.07%
TRIGGER RATES: PRES/REAL
T1[0] :373.5/7470.2 Hz T2[0] :48.5/5820.0 Hz T3[0] :228.9/228.9 Hz T4[0] :15.4/61.6 Hz T5[0] : 3.3/3.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :373.5/7469.8 Hz T2[+] :48.5/5820.3 Hz T3[+] :228.6/228.6 Hz T4[+] :15.5/61.9 Hz T5[+] : 3.3/3.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :373.6/7471.8 Hz T2[-] :48.5/5819.8 Hz T3[-] :229.3/229.3 Hz T4[-] :15.3/61.3 Hz T5[-] : 3.3/3.3 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 627388/12547776 T2[0] : 81466/9775929 T3[0] : 384537/384537 T4[0] : 25861/103444 T5[0] : 5563/5563 T8[0] : 26/1720013
T1[+] : 308006/6160138 T2[+] : 39998/4799856 T3[+] : 188550/188550 T4[+] : 12767/51069 T5[+] : 2712/2712 T8[+] : 12/844467
T1[-] : 308069/6161395 T2[-] : 39992/4799109 T3[-] : 189062/189062 T4[-] : 12630/50521 T5[-] : 2752/2752 T8[-] : 12/844408
AVERAGE CURRENT
BCM x1 : 23.8861uA BCM x3 : 23.9474uA BCM x10: 23.9379uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 65.19 ppm BCM u3 : 60.09 ppm BCM u10: 57.83 ppm
BCM d1 : 68.13 ppm BCM d3 : 57.62 ppm BCM d10: 56.57 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.03923 BCM u3 [0]:0.03937 BCM u10[0]:0.03946
BCM u1 [+]:0.01926 BCM u3 [+]:0.01933 BCM u10[+]:0.01937
BCM u1 [-]:0.01926 BCM u3 [-]:0.01933 BCM u10[-]:0.01937
BCM d1 [0]:0.04101 BCM d3 [0]:0.04108 BCM d10[0]:0.04096
BCM d1 [+]:0.02014 BCM d3 [+]:0.02017 BCM d10[+]:0.02011
BCM d1 [-]:0.02013 BCM d3 [-]:0.02016 BCM d10[-]:0.02011
****************************
End-of-run EPICS data for Run Number 1266 at Sun May 5 05:41:51 EDT 2002
Left Arm D1 momentum : 2.149
Left Arm arm angle : 22.1654
Right Arm D1 momentum : 0.755996
Right Arm arm angle : 60.0751
Tiefenbach Hall A energy : 2259.95
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -0.830078
Left Arm Bottom VDC Current : 0.0488281
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1616.9
Left Arm Q1 momentum : 2.14918
Left Arm Q1 gauss meter : 0.13723
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 925.197
Left Arm Q2 momentum : 2.14862
Left Arm Q2 gauss meter : -0.4874
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 732.762
Left Arm D1 momentum : 2.149
Left Arm D1 NMR : 0.79517
Left Arm Q3 power supply current : 855.595
Left Arm Q3 momentum : 2.1491
Left Arm Q3 gauss meter : 0.4282
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.33
Right Arm Q1 momentum : 0.755823
Right Arm Q1 gauss meter : 0.014275
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.251
Right Arm Q2 momentum : 0.755718
Right Arm Q2 gauss meter : -0.17205
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.518
Right Arm D1 momentum : 0.755998
Right Arm D1 NMR : 0.280542
Right Arm Q3 power supply current : 300.875
Right Arm Q3 momentum : 0.756141
Right Arm Q3 gauss meter : -0.13537
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 36.7541
Current on Unser monitor : 40.6232
Current on Upstream bcm : 36.7986
Current on Downstream bcm : 36.7097
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 37.1323
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.95
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.0142998
IPM1H04A.XPOS : 0.103032
IPM1H04A.YPOS : -0.0502969
IPM1H04B.XPOS : 0.0589937
IPM1H04B.YPOS : 0.0100367
Left Arm Collimator : 0.615381
Left LVDT HPM : -633
Left LVDT VPM : 914
HacL_HPE1313A:0_Ch58 : -0.12793
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : -0.128418
HacL_alignROLL : 0.220697
HacL_alignPITCH : -0.128792
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : -3199
Right LVDT VPM : 653
HacR_HPE1313A:0_Ch58 : -0.500488
HacR_HPE1313A:0_Ch55 : 21.6797
HacR_HPE1313A:0_Ch54 : -0.844238
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 180
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.71136
Target OTR y-position : 0.127958
Target OTR x-width : 0.586928
Target OTR y-width : 0.37624
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 1.08289
Arc OTR y-position : -3.38851
Arc OTR x-width : 2.10377
Arc OTR y-width : 1.82581
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0