NEXT
User name a-onl
Log entry time 04:52:56 on May 6, 2002
Entry number 2758
keyword=End_of_Run_1300
****************************
Run Number: 1300
End of Run Comment:
Run_type=production,beam_energy=2.260,beam_raster=on,comment_text=I = 50 uA collimators in; Raster ON; hydrogen,daq_mode=Unbuff,leftarm_p=+2.471,leftarm_theta=12.528,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=60.075,target_name=4cmH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=50 ps2=150 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 1000452 [+]: 490661 [-]: 491640
TIME [0]: 22.042 mins [+]: 10.821 mins [-]: 10.820 mins
LIVE [0]: 88.07% [+]: 88.03% [-]: 88.12%
TRIGGER RATES: PRES/REAL
T1[0] :363.4/18172.3 Hz T2[0] :64.8/9718.6 Hz T3[0] :329.2/329.2 Hz T4[0] :97.8/195.6 Hz T5[0] : 3.7/3.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :363.3/18165.5 Hz T2[+] :64.8/9716.4 Hz T3[+] :328.6/328.6 Hz T4[+] :98.0/196.0 Hz T5[+] : 3.7/3.7 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :363.6/18179.0 Hz T2[-] :64.8/9721.2 Hz T3[-] :329.7/329.7 Hz T4[-] :97.5/195.1 Hz T5[-] : 3.7/3.7 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 480668/24033423 T2[0] : 85687/12853111 T3[0] : 435335/435335 T4[0] : 129349/258699 T5[0] : 4915/4915 T8[0] : 20/1354269
T1[+] : 235876/11793846 T2[+] : 42055/6308277 T3[+] : 213370/213370 T4[+] : 63631/127263 T5[+] : 2431/2431 T8[+] : 10/664825
T1[-] : 236033/11801669 T2[-] : 42073/6310956 T3[-] : 214062/214062 T4[-] : 63326/126652 T5[-] : 2395/2395 T8[-] : 10/664774
AVERAGE CURRENT
BCM x1 : 48.0898uA BCM x3 : 48.2057uA BCM x10: 47.5444uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 228.2 ppm BCM u3 : 218.9 ppm BCM u10: 212.5 ppm
BCM d1 : 230.3 ppm BCM d3 : 214.4 ppm BCM d10: 156.1 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.06216 BCM u3 [0]:0.06245 BCM u10[0]:0.06242
BCM u1 [+]:0.03052 BCM u3 [+]:0.03066 BCM u10[+]:0.03065
BCM u1 [-]:0.03051 BCM u3 [-]:0.03065 BCM u10[-]:0.03064
BCM d1 [0]:0.06504 BCM d3 [0]:0.06506 BCM d10[0]:0.06334
BCM d1 [+]:0.03194 BCM d3 [+]:0.03195 BCM d10[+]:0.0311
BCM d1 [-]:0.03192 BCM d3 [-]:0.03193 BCM d10[-]:0.03109
****************************
End-of-run EPICS data for Run Number 1300 at Mon May 6 04:52:44 EDT 2002
Left Arm D1 momentum : 2.471
Left Arm arm angle : 12.5276
Right Arm D1 momentum : 0.755996
Right Arm arm angle : 60.0751
Tiefenbach Hall A energy : 2259.96
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -1.51367
Left Arm Bottom VDC Current : 2.53906
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1859.27
Left Arm Q1 momentum : 2.47134
Left Arm Q1 gauss meter : 0.15767
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1064.09
Left Arm Q2 momentum : 2.47119
Left Arm Q2 gauss meter : -0.5603
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 851.054
Left Arm D1 momentum : 2.471
Left Arm D1 NMR : 0.914546
Left Arm Q3 power supply current : 983.752
Left Arm Q3 momentum : 2.471
Left Arm Q3 gauss meter : 0.4925
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.4
Right Arm Q1 momentum : 0.755917
Right Arm Q1 gauss meter : 0.014275
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.287
Right Arm Q2 momentum : 0.755836
Right Arm Q2 gauss meter : -0.17206
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.519
Right Arm D1 momentum : 0.755999
Right Arm D1 NMR : 0.280542
Right Arm Q3 power supply current : 300.785
Right Arm Q3 momentum : 0.755913
Right Arm Q3 gauss meter : -0.13533
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 48.9274
Current on Unser monitor : 53.4587
Current on Upstream bcm : 48.8389
Current on Downstream bcm : 49.0159
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 49.3335
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.96
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 0.40573
IPM1C12.XPOS : 0.00744295
IPM1H04A.XPOS : 0.0860466
IPM1H04A.YPOS : -0.0491038
IPM1H04B.XPOS : 0.0262269
IPM1H04B.YPOS : -0.0306429
Left Arm Collimator : 0.615381
Left LVDT HPM : -993
Left LVDT VPM : 127
HacL_HPE1313A:0_Ch58 : -0.23584
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.109863
HacL_alignROLL : 0.444858
HacL_alignPITCH : -0.0533058
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : -3123
Right LVDT VPM : 584
HacR_HPE1313A:0_Ch58 : -0.501465
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.843262
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 210
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.67275
Target OTR y-position : 0.110497
Target OTR x-width : 0.566537
Target OTR y-width : 0.3876
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 1.08314
Arc OTR y-position : -3.23829
Arc OTR x-width : 2.14743
Arc OTR y-width : 1.90811
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0