NEXT
User name a-onl
Log entry time 10:24:36 on May 6, 2002
Entry number 2788
keyword=End_of_Run_1312
****************************
Run Number: 1312
End of Run Comment:
Run_type=production,beam_energy=2.260,beam_raster=on,comment_text=I = 50 uA; collimators in; 4cm LH2,daq_mode=Unbuff,leftarm_p=+2.471,leftarm_theta=12.528,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=60.075,target_name=4cmLH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=50 ps2=150 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 1001695 [+]: 491495 [-]: 491668
TIME [0]: 21.981 mins [+]: 10.788 mins [-]: 10.789 mins
LIVE [0]: 87.51% [+]: 87.57% [-]: 87.46%
TRIGGER RATES: PRES/REAL
T1[0] :368.0/18402.4 Hz T2[0] :65.2/9776.6 Hz T3[0] :332.2/332.2 Hz T4[0] :98.7/197.4 Hz T5[0] : 3.8/3.8 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :368.1/18405.8 Hz T2[+] :65.2/9774.1 Hz T3[+] :331.4/331.4 Hz T4[+] :98.7/197.5 Hz T5[+] : 3.8/3.8 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :367.9/18396.7 Hz T2[-] :65.2/9777.2 Hz T3[-] :332.9/332.9 Hz T4[-] :98.7/197.3 Hz T5[-] : 3.8/3.8 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 485396/24269846 T2[0] : 85958/12893797 T3[0] : 438077/438077 T4[0] : 130201/260402 T5[0] : 4963/4963 T8[0] : 20/1350496
T1[+] : 238274/11913720 T2[+] : 42177/6326610 T3[+] : 214477/214477 T4[+] : 63909/127818 T5[+] : 2435/2435 T8[+] : 10/662815
T1[-] : 238182/11909120 T2[-] : 42195/6329292 T3[-] : 215471/215471 T4[-] : 63876/127753 T5[-] : 2432/2432 T8[-] : 10/662888
AVERAGE CURRENT
BCM x1 : 48.7058uA BCM x3 : 48.8233uA BCM x10: 48.0361uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 255.8 ppm BCM u3 : 246.3 ppm BCM u10: 238.1 ppm
BCM d1 : 259.7 ppm BCM d3 : 241.1 ppm BCM d10: 181.5 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.06276 BCM u3 [0]:0.06305 BCM u10[0]:0.06298
BCM u1 [+]:0.03081 BCM u3 [+]:0.03095 BCM u10[+]:0.03092
BCM u1 [-]:0.0308 BCM u3 [-]:0.03094 BCM u10[-]:0.03091
BCM d1 [0]:0.06571 BCM d3 [0]:0.06573 BCM d10[0]:0.06372
BCM d1 [+]:0.03226 BCM d3 [+]:0.03227 BCM d10[+]:0.03128
BCM d1 [-]:0.03224 BCM d3 [-]:0.03225 BCM d10[-]:0.03127
****************************
End-of-run EPICS data for Run Number 1312 at Mon May 6 10:24:28 EDT 2002
Left Arm D1 momentum : 2.47099
Left Arm arm angle : 12.5276
Right Arm D1 momentum : 0.755999
Right Arm arm angle : 60.0751
Tiefenbach Hall A energy : 2259.94
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -2.14844
Left Arm Bottom VDC Current : -2.49023
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1859.2
Left Arm Q1 momentum : 2.47125
Left Arm Q1 gauss meter : 0.15768
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1063.83
Left Arm Q2 momentum : 2.47058
Left Arm Q2 gauss meter : -0.5603
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 851.054
Left Arm D1 momentum : 2.47099
Left Arm D1 NMR : 0.914545
Left Arm Q3 power supply current : 983.823
Left Arm Q3 momentum : 2.47111
Left Arm Q3 gauss meter : 0.4925
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.4
Right Arm Q1 momentum : 0.755917
Right Arm Q1 gauss meter : 0.014282
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.19
Right Arm Q2 momentum : 0.755609
Right Arm Q2 gauss meter : -0.17204
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.518
Right Arm D1 momentum : 0.755999
Right Arm D1 NMR : 0.280542
Right Arm Q3 power supply current : 300.847
Right Arm Q3 momentum : 0.75607
Right Arm Q3 gauss meter : -0.13543
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 50.0533
Current on Unser monitor : 54.4812
Current on Upstream bcm : 49.9163
Current on Downstream bcm : 50.1903
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 50.2976
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.94
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 0.337024
IPM1C12.XPOS : -0.00815439
IPM1H04A.XPOS : 0.0807713
IPM1H04A.YPOS : -0.0349722
IPM1H04B.XPOS : 0.0611707
IPM1H04B.YPOS : 0.00239008
Left Arm Collimator : 0.615381
Left LVDT HPM : -998
Left LVDT VPM : 106
HacL_HPE1313A:0_Ch58 : -0.23584
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.108887
HacL_alignROLL : 0.444088
HacL_alignPITCH : -0.0543241
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : -3120
Right LVDT VPM : 562
HacR_HPE1313A:0_Ch58 : -0.500488
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.843262
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 210
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.65813
Target OTR y-position : 0.113661
Target OTR x-width : 0.57
Target OTR y-width : 0.388365
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 1.01224
Arc OTR y-position : -3.26921
Arc OTR x-width : 2.16302
Arc OTR y-width : 1.86496
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0