NEXT
User name a-onl
Log entry time 19:03:58 on May 6, 2002
Entry number 2812
keyword=End_of_Run_1320
****************************
Run Number: 1320
End of Run Comment:
Run_type=other,beam_energy=2.260,beam_raster=off,comment_text=Carbon pointing run; changed prescalers PS1=1, PS2=100, PS3=1, PS4=1, PS5=1; collimators in; Thick carbon,daq_mode=Unbuff,leftarm_p=+2.149,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=-0.855,rightarm_theta=71.481,target_name=Thick Carbon,target_type=Carbon (thick)
PRESCALE FACTORS:ps1=1 ps2=100 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 734962 [+]: 361154 [-]: 360383
TIME [0]: 9.034 mins [+]: 4.434 mins [-]: 4.435 mins
LIVE [0]: 73.58% [+]: 73.60% [-]: 73.57%
TRIGGER RATES: PRES/REAL
T1[0] :275.6/275.6 Hz T2[0] :86.6/8660.8 Hz T3[0] :1292.2/1292.2 Hz T4[0] :184.3/184.3 Hz T5[0] : 3.9/3.9 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :275.0/275.0 Hz T2[+] :86.7/8668.0 Hz T3[+] :1294.1/1294.1 Hz T4[+] :184.5/184.5 Hz T5[+] : 3.9/3.9 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :276.2/276.2 Hz T2[-] :86.6/8655.7 Hz T3[-] :1290.3/1290.3 Hz T4[-] :184.1/184.1 Hz T5[-] : 4.0/4.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 149383/149383 T2[0] : 46944/4694420 T3[0] : 700424/700424 T4[0] : 99908/99908 T5[0] : 2139/2139 T8[0] : 8/555040
T1[+] : 73167/73167 T2[+] : 23062/2306293 T3[+] : 344331/344331 T4[+] : 49093/49093 T5[+] : 1035/1035 T8[+] : 4/272454
T1[-] : 73478/73478 T2[-] : 23030/2303094 T3[-] : 343311/343311 T4[-] : 48997/48997 T5[-] : 1052/1052 T8[-] : 4/272463
AVERAGE CURRENT
BCM x1 : 70.2869uA BCM x3 : 70.4421uA BCM x10: 62.8150uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 55.22 ppm BCM u3 : 54.02 ppm BCM u10: 41.87 ppm
BCM d1 : 58.04 ppm BCM d3 : 54.61 ppm BCM d10: 18.66 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.03721 BCM u3 [0]:0.03739 BCM u10[0]:0.03554
BCM u1 [+]:0.01827 BCM u3 [+]:0.01835 BCM u10[+]:0.01745
BCM u1 [-]:0.01826 BCM u3 [-]:0.01835 BCM u10[-]:0.01745
BCM d1 [0]:0.03899 BCM d3 [0]:0.03898 BCM d10[0]:0.03255
BCM d1 [+]:0.01914 BCM d3 [+]:0.01913 BCM d10[+]:0.01598
BCM d1 [-]:0.01914 BCM d3 [-]:0.01913 BCM d10[-]:0.01598
****************************
End-of-run EPICS data for Run Number 1320 at Mon May 6 19:03:49 EDT 2002
Left Arm D1 momentum : 2.14901
Left Arm arm angle : 22.166
Right Arm D1 momentum : 0.854999
Right Arm arm angle : 71.4811
Tiefenbach Hall A energy : 2259.95
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : 1.9043
Left Arm Bottom VDC Current : -1.9043
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1616.9
Left Arm Q1 momentum : 2.14918
Left Arm Q1 gauss meter : 0.13732
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 925.514
Left Arm Q2 momentum : 2.14936
Left Arm Q2 gauss meter : -0.4874
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 732.248
Left Arm D1 momentum : 2.149
Left Arm D1 NMR : 0.795172
Left Arm Q3 power supply current : 855.619
Left Arm Q3 momentum : 2.14916
Left Arm Q3 gauss meter : 0.4282
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 642.845
Right Arm Q1 momentum : 0.854921
Right Arm Q1 gauss meter : -0.016033
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 368.056
Right Arm Q2 momentum : 0.855213
Right Arm Q2 gauss meter : 0.19347
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 293.626
Right Arm D1 momentum : 0.854999
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.19
Right Arm Q3 momentum : 0.854944
Right Arm Q3 gauss meter : 0.1525
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 68.948
Current on Unser monitor : 73.8164
Current on Upstream bcm : 68.7294
Current on Downstream bcm : 69.1666
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 69.0354
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.95
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 0.367571
IPM1C12.XPOS : -0.00652474
IPM1H04A.XPOS : 0.0557873
IPM1H04A.YPOS : -0.0226586
IPM1H04B.XPOS : 0.046382
IPM1H04B.YPOS : -0.00868937
Left Arm Collimator : 0.61543
Left LVDT HPM : -1563
Left LVDT VPM : 945
HacL_HPE1313A:0_Ch58 : -0.124023
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.144531
HacL_alignROLL : 0.205461
HacL_alignPITCH : -0.132945
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : -2334
Right LVDT VPM : 860
HacR_HPE1313A:0_Ch58 : -0.517578
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.76709
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 255
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -5.5589
Target OTR y-position : 7.08516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 1.19176
Arc OTR y-position : -2.81771
Arc OTR x-width : 2.18161
Arc OTR y-width : 1.86823
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0