NEXT
User name a-onl
Log entry time 19:54:35 on May 6, 2002
Entry number 2817
keyword=End_of_Run_1322
****************************
Run Number: 1322
End of Run Comment:
Run_type=coincidence,beam_energy=2.260,beam_raster=on,comment_text=4cm liquid hydrogen; I ~ 70uA prescalers PS1=1, PS2=100, PS3=1, PS4=1, PS5=1; collimators in; Thick carbon,daq_mode=Unbuff,leftarm_p=+2.149,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=-0.855,rightarm_theta=71.481,target_name=4cm LH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=1 ps2=100 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 1000515 [+]: 490798 [-]: 491414
TIME [0]: 27.127 mins [+]: 13.317 mins [-]: 13.319 mins
LIVE [0]: 83.91% [+]: 83.86% [-]: 83.94%
TRIGGER RATES: PRES/REAL
T1[0] :55.1/55.1 Hz T2[0] :60.8/6079.8 Hz T3[0] :483.4/483.4 Hz T4[0] :116.3/116.3 Hz T5[0] :17.0/17.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :55.3/55.3 Hz T2[+] :60.8/6080.6 Hz T3[+] :483.2/483.2 Hz T4[+] :116.1/116.1 Hz T5[+] :17.0/17.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :54.9/54.9 Hz T2[-] :60.8/6080.1 Hz T3[-] :483.5/483.5 Hz T4[-] :116.3/116.3 Hz T5[-] :17.0/17.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 89725/89725 T2[0] : 98957/9895798 T3[0] : 786791/786791 T4[0] : 189270/189270 T5[0] : 27648/27648 T8[0] : 25/1666707
T1[+] : 44201/44201 T2[+] : 48584/4858412 T3[+] : 386114/386114 T4[+] : 92742/92742 T5[+] : 13583/13583 T8[+] : 12/818178
T1[-] : 43901/43901 T2[-] : 48588/4858864 T3[-] : 386413/386413 T4[-] : 92940/92940 T5[-] : 13576/13576 T8[-] : 12/818328
AVERAGE CURRENT
BCM x1 : 65.8018uA BCM x3 : 65.9481uA BCM x10: 59.0142uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 94.51 ppm BCM u3 : 93.66 ppm BCM u10: 78.27 ppm
BCM d1 : 94.34 ppm BCM d3 : 93.67 ppm BCM d10: 48.62 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1046 BCM u3 [0]:0.1051 BCM u10[0]:0.1001
BCM u1 [+]:0.05136 BCM u3 [+]:0.0516 BCM u10[+]:0.04914
BCM u1 [-]:0.05136 BCM u3 [-]:0.0516 BCM u10[-]:0.04914
BCM d1 [0]:0.1096 BCM d3 [0]:0.1096 BCM d10[0]:0.09202
BCM d1 [+]:0.05381 BCM d3 [+]:0.0538 BCM d10[+]:0.04518
BCM d1 [-]:0.05381 BCM d3 [-]:0.0538 BCM d10[-]:0.04518
****************************
End-of-run EPICS data for Run Number 1322 at Mon May 6 19:54:25 EDT 2002
Left Arm D1 momentum : 2.14901
Left Arm arm angle : 22.166
Right Arm D1 momentum : 0.854999
Right Arm arm angle : 71.4811
Tiefenbach Hall A energy : 2259.96
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : 3.75977
Left Arm Bottom VDC Current : -2.34375
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1616.9
Left Arm Q1 momentum : 2.14918
Left Arm Q1 gauss meter : 0.13731
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 925.237
Left Arm Q2 momentum : 2.14872
Left Arm Q2 gauss meter : -0.4875
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 732.245
Left Arm D1 momentum : 2.149
Left Arm D1 NMR : 0.795173
Left Arm Q3 power supply current : 855.577
Left Arm Q3 momentum : 2.14905
Left Arm Q3 gauss meter : 0.4282
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 642.845
Right Arm Q1 momentum : 0.854921
Right Arm Q1 gauss meter : -0.016045
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 368.21
Right Arm Q2 momentum : 0.855572
Right Arm Q2 gauss meter : 0.1935
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 293.627
Right Arm D1 momentum : 0.854998
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.15
Right Arm Q3 momentum : 0.854844
Right Arm Q3 gauss meter : 0.15256
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 68.7091
Current on Unser monitor : 73.1534
Current on Upstream bcm : 68.3456
Current on Downstream bcm : 68.9578
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 68.9385
MBSY1c Hall A Beam energy : 2262.69
MBSY1c magnet current (amp) : 94.162
MBSY1c Bdl : 564657
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 2259.96
Tiefenbach Hall C energy : 5564.65
Delta(E)/E width (MV_AI_DXWID) : 0.36908
IPM1C12.XPOS : 0.00872967
IPM1H04A.XPOS : 0.070026
IPM1H04A.YPOS : -0.0132175
IPM1H04B.XPOS : -0.102678
IPM1H04B.YPOS : 0.0254127
Left Arm Collimator : 0.61543
Left LVDT HPM : -1523
Left LVDT VPM : 936
HacL_HPE1313A:0_Ch58 : -0.124023
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.145508
HacL_alignROLL : 0.205387
HacL_alignPITCH : -0.133307
HacL_alignHPT : -0
Right Arm Collimator : 0.612012
Right LVDT HPM : -2311
Right LVDT VPM : 838
HacR_HPE1313A:0_Ch58 : -0.517578
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.767578
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -70.2265
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1636.3
Wien field : 46.79
Laser attenuation Hall A : 255
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -5.5589
Target OTR y-position : 7.08516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 1.09271
Arc OTR y-position : -3.19348
Arc OTR x-width : 2.16158
Arc OTR y-width : 1.87702
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0